background image

12/20/13

1-800-810-WIRE • www.sargentlock.com • A8152C        7

Copyright © 2014, Sargen

t Manufacturing Company

, an A

SS

A AB

LO

Y G

roup company

. All right

s reser

ved

Reproductions in whole or in par

t without express writ

ten permission of Sargen

t Manufacturing Company is prohibited

.

IN120 Cylindrical Lock  

A.   Verify Hand and Bevel of Door

Stand on outside of locked door when determining door hand.

Lock Installation

LH

  

Left Hand 

Hinges Left 

Open Inward 

LHRB 

 

Left Hand 

Reverse Bevel 

Hinges Left 

Open Outward 

RH

 

Right Hand 

Hinges Right 
Open Inward 

RHRB 

 

Right Hand 

Reverse Bevel 

Hinges Right 

Open Outward 

Fig. 1A

1   Prepare Door

6

B.   Prepare Door

Prior to installation, all holes must be free of burrs, debris and sharp edges. 
Prepare door according to appropriate template (see website 

www.intelligentopenings.com

).

•  Field Template: A8149 (ships with product)
•  Door Manufacturer’s Template: 4712

Inside of Door

Outside of Door

 Fig. 1B Wood Door Preparation

Cable Hole

Through-bolt 

Holes

Cable Hole

Pre-drilled  

Tap Holes 

Cylindrical

Pocket and

Latch Holes

Through-bolt Hole

External  

DPS  

holes

Through-bolt Hole

Lever Handle 

Hole

Raceway for Lock-

body Harness

Raceway for Lock-

body Harness

Summary of Contents for Assa Abloy IN120

Page 1: ...nufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited WiFi Cylindrical Lock Installation Instructions IN120 ...

Page 2: ......

Page 3: ...FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20cm between the radiator and your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Under Industry Canada regulations this radio transmitter may only operate using an antenna of a type and maximum...

Page 4: ...be replaced with alkaline batteries only Hardware Specifications 3 Complete lockset with on board memory ADA compliant Easily retrofits existing cylindrical lock door preps Latch 1 2 standard 3 4 throw fire rated double doors optional 41 prefix 4 Deadlocking latch Stainless steel non handed Lock furnished for 1 3 4 doors For other thicknesses consult factory UL Listed 3 hr Outside lever controlled...

Page 5: ...tal trim IN 120 EM01 IPS B All credentials supported by the IP option plus MIFARE Classic and DESfire EV1 Black IN 120 EM01 IPS W All credentials supported by the IP option plus MIFARE Classic and DESfire EV1 White IN 120 EM01 IPS MB finish All credentials supported by the IP option plus MIFARE Classic and DESfire EV1 Black with metal trim IN 120 EM01 IPS MW finish All credentials supported by the...

Page 6: ... 5 4 12 9 10 8 ITEM PART NO ORDER STRING DESCRIPTION QTY 1 Outside Lever Reference Catalog for Available Styles 1 2 10 0043 Lever Retainer Key In Screw Pack 10 2052 1 3 Cylinder Assembly Reference Catalog for Available Cylinders 1 4 Rose Reference Catalog for Avalable Styles 2 5 10 0792 Spacer Bushing 2 6 10 3049 Outside Rose Spring Assembly 1 7 10 3407 Lockbody Assembly 10G77 Standard Cylinder 1 ...

Page 7: ...pen Outward RH Right Hand Hinges Right Open Inward RHRB Right Hand Reverse Bevel Hinges Right Open Outward Fig 1A 1 Prepare Door 6 B Prepare Door Prior to installation all holes must be free of burrs debris and sharp edges Prepare door according to appropriate template see website www intelligentopenings com Field Template A8149 ships with product Door Manufacturer s Template 4712 Inside of Door O...

Page 8: ...letely at this time See section 8 Secure Lock to the Door 3 Install Latchbolt Fig 3B Strike IMPORTANT Latch bevel must match door bevel and deadlocking latch must stop on strike when door is closed Deadlocking Latch Inside of Door Fig 3A 4 Install Door Position Switch DPS 1 Push wires through raceway toward lock prep 2 Push DPS firmly into place by hand Note DO NOT TAP SWITCH WITH ANY TOOL 3 Insta...

Page 9: ...is prohibited IN120 Cylindrical Lock The lock is shipped preset and does not require adjustment for 1 3 4 thick doors 5 Lock Adjustments NOTE Adjusting for a thicker door requires removal of the outside lever scalp and spacer bushing see the following sections If preset lock does not require adjustment proceed to Section 7 Install Lock A Lock Preset Lockbody holes 12 and 6 o clock Fig 5 Outside of...

Page 10: ...ess lever retainer with push pin tool provided 3 Pull lever outward 6 Through Bolt and Door Thickness Adjustment If Required Outside of Door Fig 6A B How To Change Cylinder If Necessary 1 With outside lever in hand use standard pliers to pull out cylinder retainer 2 Remove key and cylinder from lever 3 Insert new cylinder 4 Secure by pressing cylinder retainer flush with the lever Cylinder Cylinde...

Page 11: ...Cylindrical Lock 1 If necessary remove outside lever scalp and spacer bushing Fig 6C C Through Bolt and Door Thickness Adjustment Fig 6C Fig 6C Detail 1 3 4 Thick Doors 2 Thick Doors 2 Rotate mounting plate to either align with through bolt holes in door or adjust for proper door thickness Fig 6D Refer to markings on through bolt post Fig 6C Detail 3 Re install spacer bushing to align with back of...

Page 12: ...or Feed harness through inside of door not shown 2 Continue to feed harness into raceway towards top of door exiting raceway hole on inside of door Fig 7B 3 Slide lockbody into cross bore hole from outside of door 4 Lockbody must engage both the latch unit prongs and tail piece Fig 7C IMPORTANT Door must remain open during installation use door stop Lockbody must be centered in the door Tuck exces...

Page 13: ...mbly Fig 8A NOTE Proper placement of ground wire Fig 8B will prevent pinching damage to the ground wire 3 Secure rose assembly with 2 10 32x1 1 4 through bolts 4 Secure latch by fully tightening 2 6 x 3 4 self tapping screws refer to previous section 3 Install Latchbolt Fig 9 Inside of Door 9 Assemble Inside Trim 1 Verify spacer bushing is inserted horizontally and aligned with lever Fig 9 2 Place...

Page 14: ... Company is prohibited 12 20 13 IN120 Cylindrical Lock 10 Outside Reader Installation Fig 10A Outside of Door 1 Orient the reader so the LED lens is at the top 2 Feed the cable connector through the door from outside to inside 3 Install the reader to the outside of door by aligning the mounting posts with the door preparation holes Hold the reader flush against door while ensuring proper alignment...

Page 15: ... the cables connectors through the inside mounting assembly and gasket if required NOTE Cable lengths exaggerated for illustrative purposes Inside of Door Gasket 10 Outside Reader Installation Continued Mounting Plate Gasket is required for outdoor installations If installing with gasket separate gasket from mounting plate to feed cables connectors through holes as indicated Fig 10B Once cables co...

Page 16: ...s 10 Outside Reader Installation Continued Installation of Connectors E When all connections have been made tuck excess cable into wire hole on inside of door F Secure the mounting assembly by tightening the 2 through bolts on the inside of the door to secure the reader Fig 10E Fig 10E Through bolts Secure the following connectors to their respective terminals Fig 10C D A Secure the 24 pin card re...

Page 17: ...n mounting plate Fig 11A B 2 Looking down from top of controller ensure proper alignment of board to board connectors Fig 11B while pivoting controller toward door until two tabs on top snap securely into place on mounting plate Fig 11A CAUTION To avoid possible damage to board to board connectors care should be taken when securing controller to mounting plate If there is resistance when securing ...

Page 18: ...p edge on inside mounting plate 2 Carefully press bottom of cover toward door without pinching any wires 3 Secure cover utilizing security allen wrench provided AA Batteries 6 Coin Cell Pull Tab 12 Battery Installation 1 Place 6 AA alkaline batteries in the compartment being careful to align polarity properly 2 After batteries are installed there is a slight delay then an audible beep will sound a...

Page 19: ...ction against lock case wire harness or any other obstructions 2 Check that the key retracts the latch 3 The key should rotate freely 4 Try the inside lever ensure it retracts latch 5 Present a valid credential Fig 14B to unlock outside lever turn lever handle to ensure latch retracts Operational Check 7 Fig 14B Note The credential should approach the inscription on the reader as indicated Fig 14B...

Page 20: ...ion and replacement applications The company s customer base includes commercial construction institutional and industrial markets Copyright 2014 Sargent Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited ASSA ABLOY is the global leader in door opening solutions...

Reviews: