3
Copyright © 2020 SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in part
without the express written permission of SARGENT Manufacturing Company is prohibited.
1-800-727-5477 • www.sargentlock.com
A7133 12/20
10 Line
Installation Instructions
Cylindrical Lockset
To Remove:
Rotate key 45° and hold. Depress lever catch with pin tool.
To Install:
Insert key and rotate 45° clockwise, slide the lever on. Confirm the lever will not pull off.
Lever catch
To Remove:
Remove cylinder and tailpiece, using control key (stamped “C”). Insert Phillips #2 screwdriver into cylinder
opening and make contact with lever catch. Pull lever catch horizontally towards door hinge and remove
lever.
To Install:
Slide lever over lever catch. Confirm the lever will not pull off.
*Note:
For 1-Bitted cylinders, utilize a control key cut 113511.
Figure 9
Control Key*
Figure 10
IMPORTANT
10G16, 10G30, 10G54 Functions:
• Before installing cylinders, use a flat-bladed screwdriver to rotate all cams
counterclockwise until they stop (Figure 11). (Cam is located in lever support
tube of lockbody). (Figure 12)
10G26 & 10G38 Functions:
• See supplemental instruction sheet A8082.
r
Key
Outside Lever
Correct Key Orientation
During Assembly
Cylinder
Cylinder
Spacer
Washers
(only 30-option)
Figure 11
Figure 12
Lever
Support
Tube
Cam
IMPORTANT
•
Remove tailpiece from construction core and insert into new core. If using 7 pin cores,
insert the 7 pin tail piece that’s supplied with the lock, before installing the core into the lock.
•
For Degree and XC LFIC cores, retainer must be installed on tailpiece.
C
C
New Cylinder
•
Remove temporary construction core or plastic core. If keyed, use Control Key
(stamped “C”) rotate 15
°
and pull.
•
Insert permanent core into lever with control key; rotate 15
°
and remove key.
Remove
Construction Core
Install New/
Final Cylinder
Remove/Reuse 6 Pin Tailpiece
Plastic Core
7 Pin
In Core
Keyed
Core
Construction Core
6 Pin
In Core
Keyed
Core
SFIC Shown
Standard Cylinder (Figure 9)
Interchangable or Removable Core (Figure 10)
Interchangeable or Removable Core
7
Lever Removal & Installation
8