Saracen Eco IR Basin Tap Installation And Maintenance Manual Download Page 3

2

Mark the position on the wall ready for mounting; drill suitable holes, 

insert the rawl plugs and secure the control box using the screws 

provided.
Secure and tighten the flexible hose from the tap connection to the 

solenoid outlet.
Attached the other flexible hose provided to the inlet connection on the 

solenoid valve and tighten to form a seal.
This flexible hose should be connected to the water supply pipe.
The mains version is designed to take a 230V mains power supply 

and convert it using the internal transformer to a 6V supply. The mains 

power cable should have the live and neutral connected into a fused 

spur.

Please note the control box is double insulated.

The battery version 

comes supplied with 4 

x AA batteries, ensure 

these are placed in 

the battery box and 

re-secure with the 

screws. Please note: 

The mains version is 

supplied with a battery 

back-up, incase of a 

power failure.
Secure the cover onto 

the control box using 

the screws provided.
Connect the signal wire 

to the sensor wire from 

the tap.
Ensure both the wires for the battery and the

mains power supplies (if applicable)

are connected.

Deck plate
Wash basin

Plastic cushion

Faucet spout

Sensor

Deck plate

Wash basin

Signal wire

Power cable

Control box

Water inlet

Hose

Sealing nut

Hose

Lock washer
Nut
Fixed shank

Summary of Contents for Eco IR Basin Tap

Page 1: ...Installation and Maintenance Guide Eco IR Basin Tap A basin mounted tap with pre programmed infra red sensor mains or battery supply...

Page 2: ...plate on the threaded shank Feed the connection cable though the chosen hole in the basin or counter top position the tap and use the plastic cushion lock washer and nut to secure Connect the flexible...

Page 3: ...ains power cable should have the live and neutral connected into a fused spur Please note the control box is double insulated The battery version comes supplied with 4 x AA batteries ensure these are...

Page 4: ...Reconnect the power cable 3 Immediately place your hand at a distance of less than 50mm from the sensor while the red LED within the sensor is blinking 4 When the red LED stays on draw your hand back...

Page 5: ...open the cover to access the batteries 3 Replace all 4 AA batteries ensure the and are correct to the indicators on the box 4 Replace the cover on the battery box and reposition this in the control b...

Page 6: ...a mild detergent on a soft damp cloth followed by a thorough rinse and wipe dry with a soft clean cloth is all that is required Do not use an abrasive or chemical household cleaner as this may cause...

Page 7: ...within the sensor 1 Battery or power has been disconnected Check power source power cable and replace the 4 x AA batteries in the control box Water flow diminishes 1 Aerator on tap spout us clogged R...

Page 8: ...For further information please call 01926 705000 or visit www wolseley co uk Wolseley UK reserves the right to make changes to the product which may effect the accuracy of the information contained i...