background image

IP Control Box

  

SKU - RFR-IP

Wiring Instruction

The power must be cut off before wiring, prevent from static electricity as

damage to electronic parts. 

Please use cables that comply with local safety standard.  

The earth wire need to be connected. 

The loop resistance is less than 20ohm, if the cable lies nearby high current,

please use shielded wire.

Diagram

Signal light
Power light

SW5

IP input (RJ45)

Close contact

Output (RJ12)

Rs485 (RJ12)

Programming

key (SW5)

Function

switch

Manual

 buttons

 control

Close

 contact

 input

UP

ST

OP

DOWN

Manual

 Switch

Introduction

Control methods: 

1. IP control.

2. RF remote control.

3. Manual buttons control

4. Close contact control 

5. RS232/RS485. 

Features: 

Automatically power cutoff after no

operation for 2 minutes. 

One receiver can have max 20 RF

signals for individual control.

1 button switch for input /output

control.  

Signal light
Power light

Wiring 

panel

Side side

Wiring is in the bottom position after installation.

Environment: Please prevent the IP box located/covered nearby a large metal

object for RF receiver quality.

If more than one IP box installed, please separate them by at least 20cm to

avoid interference. 

Reference table

Key

Direction

Control: 

"ON" side:

“123" side:

Key 1

Key 2

Key 3

Close 

contact 

direction 

RF

control

RS232

Forward

Output

Output

Reverse

Input

Input

3 function switch: 
Key 1

RS232 Output: to control screen

RS232 Input: controlled by RS232 input
Key 2

RF Output: to control other RF product

RF Input: controlled by RF input
Key 3

Close contact output (control direction)

(

1

)

Function switch

Parameters of the receiver:

 The actual figure should refer to the

parameter sticker on the box

> Working Temprature:  -20

 to  +80

> Maximum Load: 600W

> Operating Frequency: 868MHz

Power source: AC230V/50Hz, 120V/60Hz

Installation

Remove the M3.5x6 screws to open the casing. 

Remove the M5x10 screws to open the holder. 

Insert through the ring.

Wiring connection.

holder

casing

wiring

ring

The Remote control is compatible with the IP receiver box, transfer signal Radio

wave (868MHz)

Programming & Clear for RF Remote

control: 
1. Press the programming key (SW5)       for 3

seconds, the signal light (green) will twinkle

for being in programming mode.
2. Then release the programming key(SW5), 

press up            AND stop            of the remote

controller until the signal light becomes solid.

 (Programming completed)

Programming Code Cleaning: 

(

After the Programming code is set,  perform

the same steps as Programming Code setting

above.)

6. Clear Code: FF XX XX XX A6

"XX" means Hex number other than E.  EE EE EE is the fixed code.

2

RS485/RS232 Configuration

3

Reset to factory setting (Clear memory, IP returns to 191.168.1.2)

Press Programming key (SW5) for 5 seconds until the signal light (green) flashing 

faster

,

Release the Programming key (SW5), press again, the "signal light" becomes

solid. Reset completed. 

4

Manual control

Manual control buttons

The wiring color is based on our product reference. If it is using on other screen

brand, please contact with other brand supplier for the wiring color. 

Red

RS485-D-

RS485-D+

B
A

R1

L1

Remark: After RS232 plug in

if the screen 

is not function accordingly

please reverse 

the 1P(GND) and 2P(TXD) wires

Reviews: