IP Control Box
SKU - RFR-IP
Wiring Instruction
The power must be cut off before wiring, prevent from static electricity as
damage to electronic parts.
Please use cables that comply with local safety standard.
The earth wire need to be connected.
The loop resistance is less than 20ohm, if the cable lies nearby high current,
please use shielded wire.
Diagram
Signal light
Power light
SW5
IP input (RJ45)
Close contact
Output (RJ12)
Rs485 (RJ12)
Programming
key (SW5)
Function
switch
Manual
buttons
control
Close
contact
input
UP
ST
OP
DOWN
Manual
Switch
Introduction
Control methods:
1. IP control.
2. RF remote control.
3. Manual buttons control
.
4. Close contact control
5. RS232/RS485.
Features:
Automatically power cutoff after no
operation for 2 minutes.
One receiver can have max 20 RF
signals for individual control.
1 button switch for input /output
control.
Signal light
Power light
Wiring
panel
Side side
Wiring is in the bottom position after installation.
Environment: Please prevent the IP box located/covered nearby a large metal
object for RF receiver quality.
If more than one IP box installed, please separate them by at least 20cm to
avoid interference.
Reference table
Key
Direction
Control:
"ON" side:
“123" side:
Key 1
Key 2
Key 3
Close
contact
direction
RF
control
RS232
Forward
Output
Output
Reverse
Input
Input
3 function switch:
Key 1
RS232 Output: to control screen
RS232 Input: controlled by RS232 input
Key 2
RF Output: to control other RF product
RF Input: controlled by RF input
Key 3
Close contact output (control direction)
(
1
)
Function switch
Parameters of the receiver:
>
The actual figure should refer to the
parameter sticker on the box
> Working Temprature: -20
℃
to +80
℃
> Maximum Load: 600W
> Operating Frequency: 868MHz
Power source: AC230V/50Hz, 120V/60Hz
Installation
Remove the M3.5x6 screws to open the casing.
Remove the M5x10 screws to open the holder.
Insert through the ring.
Wiring connection.
holder
casing
wiring
ring
The Remote control is compatible with the IP receiver box, transfer signal Radio
wave (868MHz)
Programming & Clear for RF Remote
control:
1. Press the programming key (SW5) for 3
seconds, the signal light (green) will twinkle
for being in programming mode.
2. Then release the programming key(SW5),
press up AND stop of the remote
controller until the signal light becomes solid.
(Programming completed)
Programming Code Cleaning:
(
After the Programming code is set, perform
the same steps as Programming Code setting
above.)
6. Clear Code: FF XX XX XX A6
"XX" means Hex number other than E. EE EE EE is the fixed code.
(
2
)
RS485/RS232 Configuration
(
3
)
Reset to factory setting (Clear memory, IP returns to 191.168.1.2)
Press Programming key (SW5) for 5 seconds until the signal light (green) flashing
faster
,
Release the Programming key (SW5), press again, the "signal light" becomes
solid. Reset completed.
(
4
)
Manual control
Manual control buttons
The wiring color is based on our product reference. If it is using on other screen
brand, please contact with other brand supplier for the wiring color.
Red
RS485-D-
RS485-D+
B
A
R1
L1
Remark: After RS232 plug in
,
if the screen
is not function accordingly
,
please reverse
the 1P(GND) and 2P(TXD) wires
Summary of Contents for RFR-IP
Page 3: ......