- 19 -
LED thousands: Power-down storage
options
0
:
storage
1
:
do not storage
F1.17
Multi-speed
frequency 1
F1.17-P1.35 to determine the operating
frequency, time and direction of each
section.
The multi-step speed frequency can be
set continuously from -upper limit
frequency (-fmax) to upper limit
frequency (fmx).
Note: The sign of the multi-step speed
determines the running direction of the
simple PLC. Negative values indicate
reverse operation. This machine can set
7-step speed frequency, corresponding
to multi-step speed frequency 0 (f0) to
multi-step speed 6 (f6)
Spee
d
segm
ent
Multi
-spee
d S1
Multi
-spee
d S2
Multi
-spee
d S3
0
1
0
0
1
0
1
0
2
1
1
0
3
0
0
1
4
1
0
1
5
0
1
1
6
1
1
1
-Upper
frequency to
upper
frequency
5.0Hz
○
F1.18
Multi-speed
frequency 2
-Upper
frequency to
upper
frequency
10.0H
z
○
F1.19
Multi-speed
frequency 3
-Upper
frequency to
upper
frequency
15.0H
z
○
F1.20
Multi-speed
frequency 4
-Upper
frequency to
upper
frequency
20.0H
z
○
F1.21
Multi-speed
frequency 5
-Upper
frequency to
upper
frequency
25.0H
z
○
F1.22
Multi-speed
frequency 6
-Upper
frequency to
upper
frequency
37.5H
z
○
F1.23
Multi-speed
frequency 7
-Upper
frequency to
upper
frequency
50.0H
z
○
F1.24
Speed
segment 1
running time
Set the running time of segment speed 1
(unit is selected by [F1.35], default is
second)
0.0
~
999.9s
10.0s
○
F1.25
Speed segment
2 running time
Set the running time of segment speed 2
(the unit is selected by [F1.35], the
default is second)
0.0
~
999.9s
10.0s
○
F1.26
Speed segment
3 running time
Set the running time of segment speed 3
(the unit is selected by [F1.35], the
default is second)
0.0
~
999.9s
10.0s
○
F1.27
Speed segment
4 running time
Set the running time of segment speed 4
(unit is selected by [F1.35], default is
second)
0.0
~
999.9s
10.0s
○
F1.28
Speed segment
5 running time
Set the running time of segment speed 5
(the unit is selected by [F1.35], the
default is second)
0.0
~
999.9s
10.0s
○
F1.29
Speed segment
6 running time
Set the running time of segment speed 6
(unit is selected by [F1.35], default is
second)
0.0
~
999.9s
10.0s
○
F1.30
Speed segment
7 running time
Set the running time of segment speed 7
(the unit is selected by [F1.35], the
default is second)
0.0
~
999.9s
10.0s
○
F1.31
segment
acceleration
and
deceleration
LED ones: Speed segment 1
acceleration and deceleration time
0
~
1
0000
~
1111
0000
○