- 13 -
ESC1
Power module
failure
Inverter output short circuit or
grounded
Check motor wiring
Iverter instantaneous overcurrent Refer to overcurrent solution
Control board abnormal or
serious interference
Ask service from the manufacturer
Power device damage
Ask service from the manufacturer
E-OH
Radiator
overheating
The ambient temperature is too
high
Decrease ambient temperature
Damaged fan
Replace the fan
Clogged air duct
Dredge air duct
EOL1
Inverter
overload
Improper setting of V / F curve or
torque boost
Adjust V / F curve and torque boost
The grid voltage is too low
Check grid voltage
The acceleration time is too short Increase acceleration time
The motor is overloaded
Choose big power inverter
EOL2 Motor overload
Improper setting of V / F curve or
torque boost
Adjust V / F curve and torque boost
The grid voltage is too low
Check grid voltage
The motor is locked or the load is
too large
Check the load
The motor overload protection
factor is set incorrectly
Correctly set the motor overload protection
factor
E-EF
External
equipment fault
Fault input terminal of the
external device is closed
Disconnect the fault input terminal of the
external device and clear the fault (Attention
to check the reason)
EPID
PID feedback
disconnected
PID feedback circuit is loose
Check the feedback connection
Feedback value is less than
broken wire detection value
Adjust the detection input threshold
E485
RS485
communication
fault
Does not match the baud rate of
the host computer
Adjust the baud rate
RS485 channel interference
Check whether the communication connection
is shielded and whether the wiring is
reasonable. If necessary, consider connecting
parallel filter capacitors
Communication timeout
Retry
ECCF
Current
detection fault
Current sampling circuit fault
Ask service from the manufacturer
Auxiliary power fault
EEEP
EEPROM read
and write fault
EEPROM fault
Ask service from the manufacturer
EPAO Burst fault
Feedback pressure is less than low
pressure detection threshold or
greater than or equal to high
pressure detection threshold
Check the feedback connection or adjust the
detection high and low pressure threshold
EPOF
Dual CPU
communication
fault
CPU communication fault
Ask service from the manufacturer