– 16 –
6-1. LCD VcomPP Adjustment
Preparation:
POWER switch: ON
Adjusting method:
1. Double-click on the DscCalDi.exe.
2. Adjust LCD “VCOMPP” so that the amplitude of the CL404
waveform is 5.45 V
±
0.1 Vp-p.
6-2. LCD VcomDC Adjustment
Adjusting method:
1. Adjust LCD “VCOMDC” so that the amplitude of the CL404
waveform is 4.02 V
±
0.05 Vp-p.
5.45 V
±
0.1 Vp-p
CL404 waveform
4.02 V
±
0.05 Vp-p
GND
CL404 waveform
Summary of Contents for Xacti VPC-S1