Connections

Operating a coaxial-type camera using a system controller

This unit can convert SSP (RS-485) signals into coaxial signals, so that a coaxial-type camera can be operated
using a system controller.

19200

9600

2400

24V AC

12V DC

GND

A

RS485

B

C

AL

ALARM

TERMINATE

CONTROL SIGNAL

ON

OFF

VIDEO

OUT

CAMERA

IN

SEPA

MIX

POWER

4800

bps

CLASS 2 WIRING

CONTROL SIGNAL

SEPA

MIX

6

2

10

14

5

1

9

13

7

3

11

15

8

4

12

16

Dome-type camera unit (PTZ)
(sold separately)

VIDEO IN
connector

VIDEO IN
connector

ALARM IN
connector

SSP
(RS-485)

SSP

(RS-485)

System controller

(sold separately)

TV monitor

(sold separately)

SSP (RS-485) signal-type multiplexer

(sold separately)

or

GND

– 4 –

English

Summary of Contents for VSP-CB10

Page 1: ...Français F Convertidor COAX SSP Español E Convertitore COAX SSP Italiano I Before installing and using this unit please read this manual carefully Be sure to keep it handy for later reference This unit converts coaxial signals to SSP signals and also SSP signals to coaxial signals L8ZBA XE VSP CB10 GB 2002 1 8 ...

Page 2: ...ke or steam where the dampness may get too high or where there is a lot of dust Protect from high temperatures Do not install close to stoves or other heat generating devices such as spotlights or where the unit could be subject to direct sunlight as that could cause deformation discoloration or other damage Be careful when installing close to the ceiling in a kitchen or boiler room as the tempera...

Page 3: ...r similar device 7 RS 485 control terminals RS485 Connect to the RS 485 control terminals of a multiplexer or system controller using twisted pair cables sold separately Connect signal A to signal A and signal B to signal B 8 Alarm terminals ALARM Connect the alarm signal from a multiplexer or camera to these terminals The C terminal is used for both the RS 485 ground and the AL ground Be sure to ...

Page 4: ...convert coaxial signals into SSP RS 485 signals so that an SSP RS 485 signal type camera can be operated using a coaxial type multiplexer 19200 9600 2400 24V AC 12V DC GND A RS485 B C AL ALARM TERMINATE CONTROL SIGNAL ON OFF VIDEO OUT CAMERA IN SEPA MIX POWER 4800 bps CLASS 2 WIRING CONTROL SIGNAL SEPA MIX SSP RS 485 SSP RS 485 6 2 10 14 5 1 9 13 7 3 11 15 8 4 12 16 System controller sold separate...

Page 5: ... DC GND A RS485 B C AL ALARM TERMINATE CONTROL SIGNAL ON OFF VIDEO OUT CAMERA IN SEPA MIX POWER 4800 bps CLASS 2 WIRING CONTROL SIGNAL SEPA MIX 6 2 10 14 5 1 9 13 7 3 11 15 8 4 12 16 Dome type camera unit PTZ sold separately VIDEO IN connector VIDEO IN connector ALARM IN connector SSP RS 485 SSP RS 485 System controller sold separately TV monitor sold separately SSP RS 485 signal type multiplexer ...

Page 6: ... Insert nuts into each of the two grooves on both sides of the converter However if using threaded fasteners such as bolts to secure the converter select bolts which will not go any more than 5 mm past the surface of the converter If longer bolts are used they may damage the converter Note Parts such as the bolts and nuts required above are not supplied with the converter and must be purchased sep...

Page 7: ...ination Operating environment Temperature 10 C 50 C Dimensions 123 W x 189 8 D x 46 H mm Weight Approx 600 g Power supply 24 V AC 12 15 V DC 100 mA 1 3 W LED illuminates when power supplied Option 1 12 V DC power supply VCA 35E 1 189 8 182 123 44 46 Unit mm 6 English ...

Page 8: ...1AC6P1P2465 L8ZBA XE 0102KP CZ SANYO Electric Co Ltd Printed in Japan L8ZBA XE VSP CB10 GB 2002 1 8 ...

Reviews: