– 17 –
AF_I_MID3: FIM3
FIM3: infinity adjustment value of focus at zoom position
middle3 (–204<=FIM3<=176)
AF_I_MID4: FIM4
FIM4: infinity adjustment value of focus at zoom position
middle4 (–171<=FIM4<=190)
AF_I_MID5: FIM5
FIM5: infinity adjustment value of focus at zoom position
middle5 (–145<=FIM5<=207)
AF_I_MID6: FIM6
FIM6: infinity adjustment value of focus at zoom position
middle6 (–127<=FIM6<=207)
AF_I_MID7: FIM7
FIM7: infinity adjustment value of focus at zoom position
middle7 (–124<=FIM7<=198)
AF_I_MID8: FIM8
FIM8: infinity adjustment value of focus at zoom position
middle8 (–134<=FIM8<=193)
AF_I_TELE: FIT
FIT: infinity adjustment value of focus at zoom position tele
(–134<=FIT<=185)
AF_I_ZP_WIDE: FIZPW
FIZPW: infinity adjustment value of zoom pulse when
adjust focus at wide (990<=FIZPW<=1010)
AF_I_ZP_MID1: FIZPM1
FIZPM1: infinity adjustment value of zoom pulse when
adjust focus at middle1 (1304<=FIZPM1<=1324)
AF_I_ZP_MID2: FIZPM2
FIZPM2: infinity adjustment value of zoom pulse when
adjust focus at middle2 (1383<=FIZPM2<=1403)
AF_I_ZP_MID3: FIZPM3
FIZPM3: infinity adjustment value of zoom pulse when
adjust focus at middle3 (1451<=FIZPM3<=1471)
AF_I_ZP_MID4: FIZPM4
FIZPM4: infinity adjustment value of zoom pulse when
adjust focus at middle4 (1516<=FIZPM4<=1536)
AF_I_ZP_MID5: FIZPM5
FIZPM5: infinity adjustment value of zoom pulse when
adjust focus at middle5 (1582<=FIZPM5<=1602)
AF_I_ZP_MID6: FIZPM6
FIZPM6: infinity adjustment value of zoom pulse when
adjust focus at middle6 (1647<=FIZPM6<=1667)
AF_I_ZP_MID7: FIZPM7
FIZPM7: infinity adjustment value of zoom pulse when
adjust focus at middle7 (1712<=FIZPM7<=1732)
AF_I_ZP_MID8: FIZPM8
FIZPM8: infinity adjustment value of zoom pulse when
adjust focus at middle8 (1778<=FIZPM8<=1798)
AF_I_ZP_TELE: FIZPT
FIZPT: infinity adjustment value of zoom pulse when
adjust focus at tele (1940<=FIZPT<=1960)
Preparation:
POWER switch: ON
If using a ready-made collimator, set to infinity.
Note:
Do not vibrate during the adjustment.
Adjustment method:
1. Set a distance of 0.5-1.0 cm between camera lens and
collimator lens when zoom tele edge. Do not touch the
each lens.
2. Set the camera so that it becomes center of the siemens
star chart in the collimator (zoom wide and tele).
3. Double-click on the DscCalDi.exe.
4. Select “Infinity Cal.” on the LCD “Test”, and click the “Yes”.
5. Lens infinity adjustment value will appear on the screen.
6. Click the OK.
Adjustment value determination is effectuated using below val-
ues.
The adjustment values fulfill the conditions below, they are de-
termined as within specifications.
Adjustment value determination
AF_I_WIDE: FIW
FIW: infinity adjustment value of focus at zoom position
wide (–339<=FIW<=29)
AF_I_MID1: FIM1
FIM1: infinity adjustment value of focus at zoom position
middle1 (–288<=FIM1<=123)
AF_I_MID2: FIM2
FIM2: infinity adjustment value of focus at zoom position
middle2 (–242<=FIM2<=156)
Dsc Calibration
x
OK
Infinity calibration :
AF_I_WIDE: -5
AF_I_MID1: -1
AF_I_MID2: 3
AF_I_MID3: 11
AF_I_MID4: 24
AF_I_MID5: 38
AF_I_MID6: 45
AF_I_MID7: 56
AF_I_MID8: 48
AF_I_TELE: 0
AF_I_ZP_WIDE: 1003
AF_I_ZP_MID1: 1313
AF_I_ZP_MID2: 1393
AF_I_ZP_MID3: 1459
AF_I_ZP_MID4: 1526
AF_I_ZP_MID5: 1591
AF_I_ZP_MID6: 1655
AF_I_ZP_MID7: 1720
AF_I_ZP_MID8: 1787
AF_I_ZP_TELE: 1949
AF_ADJ_INF_TIME: 0
Copy
When all of the lens adjustment screen
is not displayed, use a scroll bar.