– 19 –
5. CCD Black Point And White Point Defect Detect
Adjustment In Lighted
Preparation:
POWER switch: ON
Setting of pattern box:
Color temperature: 3100
±
20 (K)
Luminance: 900
±
20 (cd/m
2
)
Adjusting method:
1. Set the camera 0 cm from the pattern box. (Do not enter
any light.)
2. Double-click on the DscCalDi.exe.
3. Select “CCD Black” on the LCD “Test”, and click the “Yes”.
4. After the adjustment is completed, the number of defect
will appear.
6. LCD Panel Adjustment
[CP1 board (Side B)]
6-1. LCD VcomPP Adjustment
Preparation:
POWER switch: ON
Adjusting method:
1. Double-click on the DscCalDi.exe.
2. Select “0” in the LCD “VCOMPP”.
3. Adjust LCD “VCOMPP” so that the amplitude of the CL404
waveform is 5.60 V
±
0.1 Vp-p.
6-2. LCD VcomDC Adjustment
Adjusting method:
1. Adjust LCD “VCOMDC” so that the amplitude of the CL404
waveform is 4.40 V
±
0.05 Vp-p.
VR501
CL501
CL404
CL402
Camera
Pattern box
(color viewer)
CL404 waveform
5.60 V
±
0.1 Vp-p
CL404 waveform
4.40 V
±
0.05 Vp-p
GND
(CL402)
3-8. Factory Code Setting
1. Check the "Factory Code" display within the Setting group.
2.
For U.S.A., Canada and NTSC general area
If "FC_SANYO_U" does not appear, click on the " " mark
located on the right of the "Factory Code" display BOX and
select "FC_SANYO_U".
3.
For Europe and PAL general area
If "FC_SANYO_EX" does not appear, click on the " " mark
located on the right of the "Factory Code" display BOX and
select "FC_SANYO_EX".