![Sanyo VPC-E10 Service Manual Download Page 17](http://html.mh-extra.com/html/sanyo/vpc-e10/vpc-e10_service-manual_360595017.webp)
– 17 –
3-7. Adjust Specifications
1. Lens Adjustment (60 cm)
Preparation:
POWER switch: ON
The tester should be used to adjust the voltage between the
terminals of the power connector that is being supplied from
the power supply (voltage between the battery socket termi-
nals of the camera) to 4.1
±
0.1 V.
Adjustment condition:
Siemens star chart (A3)
Fluorescent light illumination with no flicker (incandescent light
cannot be used.)
Illumination above the subject should be 700 lux
±
10%.
Note:
Do not vibrate during the adjustment.
Adjustment method:
1. Set the siemens star chart 60
±
0.5 cm from lens surface
(zoom wide position) so that it becomes center of the
screen (zoom wide and tele).
2. Double-click on the DscCalDi.exe.
3. Click the “Focus”, and Click the “Yes”.
4. Lens adjustment value will appear on the screen.
5. Click the OK.
Adjustment value determination is effectuated using below val-
ues.
The adjustment values fulfill the conditions below, they are de-
termined as within specifications.
Adjustment value determination
PZ_SW_A_B: PZ1
PZ1: adjustment value of zoom PR switch position 1
(892<=(PZ1+PBR)<=992)
PZ_SW_B_C: PZ2
PZ2: adjustment value of zoom PR switch position 2
(962<=(PZ2+PBR)<=1072)
PZ_BR: PBR
PBR: adjustment value of zoom backrush pulse
(10<=PBR<=45)
AF_SW: ASW
ASW: adjustment value of focus PI switch position
(733<=ASW<=823)
AF_BR: ABR
ABR: adjustment value of focus backrush pulse
(0<=ABR<=5)
3-6. The adjustment item which in necessary in part exchange
COMPL PWB CP-1
Factory
Cord
Setting
Language
Setting
COMPL PWB ST-1
ASSY, FLEXIBLE PWB COMP3
LENS ASSY
Reset
Setting
Lens
Adjust-
ment
(Infinity)
AWB
Adjust-
ment
USB
storage
information
registration
CCD White
Point
Defect
Detect
Adjustment
CCD Black
Point And
White Point
Defect Detect
Adjustment
In Lighted
: Be sure to carry out the necessary adjustments after replacing the unit.
: Adjustment is possible from the menu setting screen of the camera and by using the calibration software.
Lens
Adjust-
ment
(60 cm)
Camera
60 cm 0.5 cm
Siemens
star chart
DscCalDi
x
OK
Focus Result
PZ_SW_A_B: 906
PZ_SW_B_C: 980
PZ_BR: 23
AF_SW: 804
AF_BR: 3
AF_WIDE: 9
AF_MID1: 11
AF_MID2: 15
AF_MID3: 25
AF_MID4: 26
AF_MID5: 24
AF_MID6: 19
AF_MID7: 22
AF_TELE: 17
!