![Sanyo VPC-CG65EXBK Service Manual Download Page 11](http://html.mh-extra.com/html/sanyo/vpc-cg65exbk/vpc-cg65exbk_service-manual_359458011.webp)
– 11 –
ASIC,
memory
CCD
8 bit CPU
Power voltage
Power OFF
Play back
LCD finder
3.3 V 1.2 V
+3.4 V (A)
+12 V (A), -6 V(A)
3.2 V (P ON)
2.4 V (P OFF)
OFF
OFF
32KHz
OFF
OFF
32KHz
ON
ON
4 MHz
ON
OFF
4 MHz
Table 5-3. Camera Mode
Note) 4 MHz = Main clock operation, 32 kHz = Sub clock operation
4. Power Supply Control
The 8-bit microprocessor controls the power supply for the overall system.
The following is a description of how the power supply is turned on and off. When the battery is attached, a regulated 3.2 V (power
off: 2.4 V) voltage is normally input to the 8-bit microprocessor (IC301) by IC302, so that clock counting and key scanning is
carried out even when the power switch is turned off, so that the camera can start up again. When the battery is removed, the 8-
bit microprocessor operates in sleep mode using the backup battery. At this time, the 8-bit microprocessor only carries out clock
counting, and waits in standby for the battery to be attached again. When a switch is operated, the 8-bit microprocessor supplies
power to the system as required.
The 8-bit microprocessor first sets the P ON2 signal at pin (15) and P ON signal at pin (42) to high, and then turns on the DC/DC
converter. After this, low signal is output from pin (18) so that the ASIC is set to the reset condition. After this these pins set to
high, and set to active condition. Once it is completed, the ASIC returns to the reset condition, all DC/DC converters are turned
off and the power supply to the whole system is halted.
Power switch ON - Auto power OFF
CAMERA
Table 5-2. Key Operation
3. Key Operaiton
For details of the key operation, refer to the instruction manual.
0
1
2
0
1
2
3
SCAN
OUT
SCAN
IN
V. REC
DOWN
TEST
LEFT
-
3
4
RIGHT
UP
-
PW_ON
-
-
-
-
-
-
TELE
LCD TURN
SET
WIDE
PW_TEST