20
-
3-8. Adjust Specifications
1. Lens Adjustment
Preparation:
POWER switch: ON
If using a ready-made collimator, set to infinity.
Note:
Do not vibrate during the adjustment.
Adjustment method:
1. Set a distance of 0.5-1.0 cm between camera lens and
collimator lens. Do not touch the each lens.
2. Set the camera so that it becomes center of the screen in
the collimator .
3. Double-click on the DscCalDi.exe.
4. Click the Focus, and click the Yes.
5. Lens infinity adjustment value will appear on the screen.
6. Click the OK.
3-6. The adjustment item which in necessary in part exchange
Factory
Cord
Setting
Language
Setting
Reset
Setting
Lens
Adjust-
ment
AWB
Adjust-
ment
USB
storage
information
registration
CCD White
Point
Defect
Detect
Adjustment
CCD Black
Point And
White Point
Defect
Detect
Adjustment
In Lighted
3-7. Updating the firmware
Check the firmware version immediately after the CP1 board has been replaced. If an old version is being used, interfer-
ence and errors in operation may also occur. If an old version is being used, update it with a newer version.
Refer to
3-13. Firmware uploading procedure. (Page 23)
COMPL PWB CP1
COMPL PWB VF1
COMPL PWB ST1
ASSY, FLEXIBLE PWB CA1
LENS ASSY
Camera
Collimator
: Be sure to carry out the necessary adjustments after replacing the unit.
: Adjustment is possible from the menu setting screen of the camera and by using the calibration software.
Dsc Calibration
x
OK
Focus Result
STD_AFPOS= 1881
FOCUS= -5,7,14,16
ADJ_PZPOS= 7
LENS_ERR= 0
IRIS_GAIN: -103
IRIS_OFFSET: -27