2. DISASSEMBLY
Note:
1. When disassembling and reassembling the main unit, the LCD and the battery cover, always be sure to use the air
leak tester (VJ8-0303) to test for air leaks and to check that the waterproof mechanism is functioning normally.
Refer to the Instruction Manual provided with the air leak test tool for details on how to carry out the air leak test.
2. This camera uses waterproof packing. It is recommended that you replace the waterproof packing approximately
once every year. The waterproof packing is supplied in the COMPL, MENT KIT-SV-114 (P/No. 636 110 2131) shown
in the table below. These parts can also be supplied as single parts.
Summary of waterproof maintenance parts kit
Parts name: COMPL, MENT KIT-SV-114
Parts code: 636 110 2131
NO.
DESCRIPTION
1
2
3
4
5
6
7
GASKET CABINET-SG114/J
vSPACER MIC2-SG114/J
GASKET LCD-SG114/J
PAD BATTERY-SG114/J
ADHESIVE COV BATT A-SG114
ADHESIVE COV BATT B-SG114
ADHESIVE COV BATT D-SG114
NUMBER
PAD BATTERY-SG114/J
ADHESIVE COV BATT A-SG114
CABINET
LCD
COVER
BATTERY
PARTS NO.
636 104 0174
636 107 3998
636 104 0181
636 104 0198
636 104 7173
636 104 7180
636 106 6044
GASKET CABINET-SG114/J
GASKET LCD-SG114/J
PAD BATTERY-SG114/J
ADHESIVE COV BATT A-SG114
SPACER MIC2-SG114/J
ADHESIVE COV BATT D-SG114
ADHESIVE COV BATT B-SG114
When doing an air leak test at the
LCD, these parts must be replaced.
(If these parts are not removed, it
will not be possible to do the air leak
test at the LCD.)
SECTION
List of waterproof maintenance parts kit
1
2
1
1
1
1
1