6
GND
~
~
–
+
UTP
M
4V
GND
GND
~
~
–
+
✱
3
NVT
SYNC
CAMERA
LENS
ALARM
PRIVACY MASK
PASSWORD
LANGUAGE
OPTION
y
y
y
y
y
y
y
INT
1
SET
SET
SET
SET
SET
SET
GAMMA
MOTION
POSITION
DAY/NIGHT
PRESET
MENU
y
0.45
OFF
OFF
COLOR
OFF
BACK
D/N SETTING-COLOR
EXT ALARM
1
(ALARM IN 1 or 2)
(COM)
Controller
SYSTEM DEVICE
(ex. Monitor)
b
With AC 24 V
Power Supply Connection
b
With DC 12 V
Check that +/- polarity is correct.
For the connections, use cables thicker
than 18 AWG.
For the connections, use cables thicker
than 18 AWG.
Monitor Connection
To output video signal,
select the connection of a
coaxial cable or a UTP
cable.
Connection with a communication device for remote operation
Digital Video
Recorder etc.
• Using different cables from those
specified here may attenuate the
video and/or sync signals and
interfere with correct transmission.
• RG-59U coaxial cables can be
used when distance between
devices is short, but not in duct or
aerial routing.
Cable type
Length
RG-59U (3C-2V)
250 m (273 yds) max.
RG-6U (5C-2V)
500 m (547 yds) max.
RG-11U (7C-2V)
600 m (656 yds) max.
✱
3 UTP (Unshield Twist Pair) cable: LAN Category 5 or higher
Receiver
The alarm input terminals can
also be used as terminals for
switching between color and
black/white video modes using
an external switch.
Open: Color
Close: Black/White
Make sure that
COLOR is selected.
1: ALARM IN 1 terminal
2: ALARM IN 2 terminal
Color or Black-and-White Setting