Use the
/
button to select [ALARM] in the main menu, and press the SET button.
The ALARM screen appears.
Use the
/
button to select [ALARM IN], use the
/
button to choose an alarm input
number, and press the SET button.
The ALARM IN screen corresponding to the selected alarm input number (1 or 2) appears.
Available options: 1, 2
Use the
/
button to select [POLARITY], and use the
/
button to choose the polarity for
the alarm input signal.
Available settings:
Use the
/
button to select [ACTION], and use the
/
button to select the action after the
alarm is detected.
Available settings:
To use this setting, set the zoom magnification power ([RATIO]) and the display duration ([ZOOM TIME]).
To use this setting, select whether or not to return to the previous operating conditions upon completion of
an alarm action (in [RETURN] under the item [ACTION]).
1
2
When the alarm input is used as the external control input of the DAY/NIGHT function, “D/N” appears
in the top right of the screen.
In this case, settings other than [POLARITY] cannot be made.
When [EXT ALARM] for [DAY/NIGHT (COLOR)] is set to “OFF”, “D/N” disappears.
3
NO (Normal Open): Normally open so closed condition is detected as input.
NC (Normal Close): Normally closed so open condition is detected as input.
4
OFF: Does not perform any actions.
ZOOM: Zooms into the video at the specified magnification power.
CAM1/CAM2: Uses the operating conditions you configured for Camera 1 or Camera 2 in [CAMERA] on
the main menu to monitor surveillance points.
48 / 100
Summary of Contents for VCC-XZ600P
Page 52: ...52 100 ...
Page 61: ...61 100 ...
Page 73: ...73 100 ...
Page 75: ...75 100 ...
Page 81: ...81 100 ...
Page 92: ...Weight Without sunshade Approx 1 8 kg With sunshade Approx 2 0 g 92 100 ...