SETTINGS AND ADJUSTMENTS
Line phase adjustment
When using a camera switcher to connect two cameras or more to one monitor, there may be
a vertical roll of the images when switched, if the phases differ. In such a case, adjust as
described below.
1
Set the SYC switch, on the connected cameras, to 1.
2
Using the camera switcher, switch the display on the monitor from camera 1 to
camera 2.
Adjust the
L-PHASE
volume control on camera 2 until the vertical roll of the image stops.
If more than two cameras are used, please repeat this procedure for all the cameras.
NOTE:
If the vertical roll cannot be corrected by adjusting the
L-PHASE
volume on camera 2, try
adjusting the
L-PHASE
volume on camera 1. If it still cannot be corrected, please check that
the polarity of the power cords of all connected devices is correct.
SYC
1
0
L-PHASE
1
2
3 4
IN IN
OUT
Camera 1
Camera 2
SYC
1
0
L-PHASE
L53D4/US GB 1998, 3, 10
English
13