750 

±

 10 mVp-p

3-12. CCD White Point Defect Detect Adjustment

Measuring location: 

VIDEO OUT

Measuring equipment: 

Monitor display

Adjustment method:

1. Shield light with a lens cap to provide dark condition.
2. Set the camera mode, and click the “AUTO” at the WDD on

the adjustment software.

3. After completing this adjustment, it comfirms that white point

can not be seen on the monitor display.

4. Click the End button.

VIDEO OUTPUT

3-10. Iris Level Adjustment

Adjustment location: 

S3001, VR301 (CA-3)

Measuring location: 

VIDEO OUT

Measuring equipment: 

Oscilloscope

Subject:

 Gray scale chart

Adjusting method:

1. Set S3001 to the DC type lens side.
2. Attach the DC type automatic iris lens. (Use a VCL-CS8LY

or equivalent as the lens).

3. Display the gray scale chart on full screen.
4. Turn the VR301 to the right so that the white level is maxi-

mum.

5. Turn the VR301 to the left so that the output level is 750 

±

10 mVp-p.

3-11. Line Phase Adjustment

Adjustment location: 

S3002-9 (CA-3), VR402 (CA-4)

Measuring location: 

VIDEO OUT, 24 V AC/GND terminals

Measuring equipment: 

Oscilloscope

Subject:

 Attach the lens cap

Adjusting method:

1. Connect the camera to a 24 V AC /50 Hz power source.
2. Set S3002-9 switch to the “L-L” (ON) position.
3. The HOT (signal) side and the COLD (GND) side of the

oscilloscope probe connect to the right side and the left side
of the 24 VAC terminals respectively. (rear view)

4. Turn VR402 (LINE PHASE) to adjust the leading edge of

the vertical sync signal and zero-cross shift of the AC 24 V
power supply to 0 

±

 0.2 msec.

5. Set S3002-9 to the “INT” (OFF) position before shipment.

R

YL

MG

Cy

G

B

75%

100%

cy

g

yl

mg

b

U

v

YL

R

W

24 V AC

TP123

zero cross
point

0    0.2 msec.

VIDEO OUT

Summary of Contents for VCC-6594P

Page 1: ...t and pull out the bottom cabinet 5 Remove the front panel 7 Remove the four screws and then disconnect the connector 8 Remove the five screws then remove the CA 2 CA 3 board assemblies and the FPC and disconnect the connector 9 Remove the five screws and then remove the lens mount bracket 10 Remove the two screws and then remove the CA 1 board assembly CA 3 board CA 4 board CA 2 board CA 1 board ...

Page 2: ...N CA 2 board CA 4 board CA 3 board CA 1 board TP401 S3002 ON S3001 CA 1 board Side B CA 3 board Side A CA 4 board Side B TP103 TP403 VR403 VR302VR303 VR301 DC VIDEO CT232 TP232 CA 2 board Side B CT221 TP221 VR402 Side A ...

Page 3: ...6 Ground test point are TP103 CA 1 and TP401 CA 4 7 Set the distance from the subject to about 60 cm and adjust the camera position so that the picture frame size becomes as shown below when performing the adjustment with the gray scale chart ITE gray scale chart γ 0 45 8 Apply 24 V AC to the 24 V AC terminal on the camera 3 2 PREPARATION 1 Install the adjustment software VHJ 0133 in a computer ru...

Page 4: ... screen Measuring location VIDEO OUT Measuring equipment Oscilloscope Subject Gray scale chart Adjusting method 1 Click the adjustment software installed from the personal computer and the adjustment window will be displayed 2 Display the grayscale chart on full screen 3 Gradually move the lens aperture from the CLOSE side to the OPEN side and secure the aperture at the point where the AGC starts ...

Page 5: ...e gray scale chart on full screen 4 Turn the VR301 to the right so that the white level is maxi mum 5 Turn the VR301 to the left so that the output level is 750 10 mVp p 3 11 Line Phase Adjustment Adjustment location S3002 9 CA 3 VR402 CA 4 Measuring location VIDEO OUT 24 V AC GND terminals Measuring equipment Oscilloscope Subject Attach the lens cap Adjusting method 1 Connect the camera to a 24 V...

Reviews: