3-3. TABLE FOR SERVICING TOOLS

Connect the adjustment jig and camera with commander cable
(VHJ-0126)

3-3-1. Computer screen during adjustment

3-4. Power Voltage Adjustment

Adjustment location: 

VR403 (CA-4)

Measuring location:

 TP403 (CA-4)

Measuring equipment:

 Digital voltmeter

Subject:

 No designation

Adjusting method:

1. Adjust with VR403 to 3.42 

±

 0.02 V.

3-5. Sub Carrier Frequency Adjustment

Adjustment location: 

CT221 (CA-2)

Measuring location: 

TP221 (CA-2)

Measuring equipment: 

Frequency counter

Subject:

 No designation

Adjusting method:

1. Adjust with CT221 to 4433619 Hz 

±

 10 Hz.

3. ADJUSTMENT

3-1. ADJUSTMENT CONDITION

1. Use the 5,100K viewer for the subject.
2. Set the trigger signal of oscilloscope to VIDEO OUT, and

apply H sync unless specified.

3. Set S3002 to the “all OFF” position and S3001 to the “DC”

position.

4. In adjustments without direction to display charts, shield light

with a lens cap to provide dark condition. The amount of
light is to be stable.

5. Connect the video output to a video monitor with an input

impedance of 75 

.

6. Ground test point are TP103 (CA-1) and TP401 (CA-4).
7. Set the distance from the subject to about 60 cm and adjust

the camera position so that the picture frame size becomes
as shown below when performing the adjustment with the
gray scale chart (ITE gray scale chart/ 

γ 

= 0.45).

8. Apply 24 V AC to the 24 V AC terminal on the camera.

3-2. PREPARATION

1. Install the adjustment software (VHJ-0133) in a computer

running the Windows operating system.

2. Use the adjustment tool (VHJ-0127) to connect the camera

to be adjusted to the serial port of the computer, and then
turn on the power for the computer and the camera.

VIDEO OUTPUT

Commander cable (VHJ-0126)

Ref. No.

Name

Part code

J-1

J-2

J-3

VJ8-0007

VJ8-0009

Color viewer

Gray scale chart

Color bar chart

VJ8-0010

AGC

R GAIN

R HUE

B GAIN

B HUE

WDD

L53H Series Adjustment

x

0

0

0

0

0

AUTO

STATUS

START

END

CLOSE

ROM CORRECTION

FILE NAME

J-4

J-5

J-6

VHJ-0126

VHJ-0133

Commander cable

Adjustment jig

Calibration software

VHJ-0127

L: Distance from CS mount to pattern (mm)

H: Pattern height (mm)

f : Lens focal length (standard 12 mm)

h: Height (4.8 mm) of CCD imaging surface

Note

 : The video monitor should be an under-scan TV.

L =                 x f – 12.5 mm

 (H + h)

2

 H x h

L

CS mount surface

CCD camera

5,100 K viewer

H

Summary of Contents for VCC-6594P

Page 1: ...t and pull out the bottom cabinet 5 Remove the front panel 7 Remove the four screws and then disconnect the connector 8 Remove the five screws then remove the CA 2 CA 3 board assemblies and the FPC and disconnect the connector 9 Remove the five screws and then remove the lens mount bracket 10 Remove the two screws and then remove the CA 1 board assembly CA 3 board CA 4 board CA 2 board CA 1 board ...

Page 2: ...N CA 2 board CA 4 board CA 3 board CA 1 board TP401 S3002 ON S3001 CA 1 board Side B CA 3 board Side A CA 4 board Side B TP103 TP403 VR403 VR302VR303 VR301 DC VIDEO CT232 TP232 CA 2 board Side B CT221 TP221 VR402 Side A ...

Page 3: ...6 Ground test point are TP103 CA 1 and TP401 CA 4 7 Set the distance from the subject to about 60 cm and adjust the camera position so that the picture frame size becomes as shown below when performing the adjustment with the gray scale chart ITE gray scale chart γ 0 45 8 Apply 24 V AC to the 24 V AC terminal on the camera 3 2 PREPARATION 1 Install the adjustment software VHJ 0133 in a computer ru...

Page 4: ... screen Measuring location VIDEO OUT Measuring equipment Oscilloscope Subject Gray scale chart Adjusting method 1 Click the adjustment software installed from the personal computer and the adjustment window will be displayed 2 Display the grayscale chart on full screen 3 Gradually move the lens aperture from the CLOSE side to the OPEN side and secure the aperture at the point where the AGC starts ...

Page 5: ...e gray scale chart on full screen 4 Turn the VR301 to the right so that the white level is maxi mum 5 Turn the VR301 to the left so that the output level is 750 10 mVp p 3 11 Line Phase Adjustment Adjustment location S3002 9 CA 3 VR402 CA 4 Measuring location VIDEO OUT 24 V AC GND terminals Measuring equipment Oscilloscope Subject Attach the lens cap Adjusting method 1 Connect the camera to a 24 V...

Reviews: