background image

– 2 –

1. DISASSEMBLY

1. Loosen the two screws, 
    and then remove the left
    and right side panels.

2. Remove the rear panel.

3. Remove the two screws, 
    and then pull out the top cabinet.

4. Remove the two screws, and then remove 
    the bracket and pull out the bottom cabinet.

5. Remove the front panel.

7. Remove the four screws, and then 
    disconnect the connector.

8. Remove the five screws, then remove
    the CA-2/CA-3 board assemblies and 
    the FPC, and disconnect the connector.

9. Remove the five screws, and then
    remove the lens mount bracket.

10. Remove the two
      screws, and then
      remove the CA-1
      board assembly.

CA-3
board

CA-4 board

CA-2 board

CA-1 board

6. Remove the connector.

Summary of Contents for VCC-6594P

Page 1: ...t and pull out the bottom cabinet 5 Remove the front panel 7 Remove the four screws and then disconnect the connector 8 Remove the five screws then remove the CA 2 CA 3 board assemblies and the FPC and disconnect the connector 9 Remove the five screws and then remove the lens mount bracket 10 Remove the two screws and then remove the CA 1 board assembly CA 3 board CA 4 board CA 2 board CA 1 board ...

Page 2: ...N CA 2 board CA 4 board CA 3 board CA 1 board TP401 S3002 ON S3001 CA 1 board Side B CA 3 board Side A CA 4 board Side B TP103 TP403 VR403 VR302VR303 VR301 DC VIDEO CT232 TP232 CA 2 board Side B CT221 TP221 VR402 Side A ...

Page 3: ...6 Ground test point are TP103 CA 1 and TP401 CA 4 7 Set the distance from the subject to about 60 cm and adjust the camera position so that the picture frame size becomes as shown below when performing the adjustment with the gray scale chart ITE gray scale chart γ 0 45 8 Apply 24 V AC to the 24 V AC terminal on the camera 3 2 PREPARATION 1 Install the adjustment software VHJ 0133 in a computer ru...

Page 4: ... screen Measuring location VIDEO OUT Measuring equipment Oscilloscope Subject Gray scale chart Adjusting method 1 Click the adjustment software installed from the personal computer and the adjustment window will be displayed 2 Display the grayscale chart on full screen 3 Gradually move the lens aperture from the CLOSE side to the OPEN side and secure the aperture at the point where the AGC starts ...

Page 5: ...e gray scale chart on full screen 4 Turn the VR301 to the right so that the white level is maxi mum 5 Turn the VR301 to the left so that the output level is 750 10 mVp p 3 11 Line Phase Adjustment Adjustment location S3002 9 CA 3 VR402 CA 4 Measuring location VIDEO OUT 24 V AC GND terminals Measuring equipment Oscilloscope Subject Attach the lens cap Adjusting method 1 Connect the camera to a 24 V...