CONNECTIONS
Basic connection for monitoring or recording
The peripheral devices (VCR, monitor, lens, etc.), AC adaptor
and cables are sold separately.
1
Make the video signal connection between the camera and
the monitor or time lapse VCR.
2
Use a commercially available 24 V AC adaptor.
Connect an AC 24 V power source to the 24 V AC connectors on
the back of the camera.
2A:
When using this unit, the supplied clamping core (A) must be
installed on the power cord and BNC cable, in order to prevent
electromagnetic interference to the other devices connected.
3
Insert the plug of this power cord into a wall outlet.
The
POWER
indicator
(A)
will light. Adjust the picture on the
monitor using the Brightness and Contrast controls etc.
Coaxial cable type and maximum length
•
Cable type RG-59U (3C-2V), 250 m maximum.
•
Cable type RG-6U (5C-2V), 500 m maximum.
•
Cable type RG-11U (7C-2V), 600 m maximum.
CAUTION:
•
The RG-59U type cable should not be run through electrical
conduits or through the air.
•
Using CCTV/Video-grade coaxial cable.
(Video signal connections)
: VIDEO IN
: VIDEO OUT
(A)
1
3
AC 24 V connection
Push to insert the cable
AC 24 V
GND
~
~
2A
2A
2
L53X4/XE GB 2001, 2, 23
English
9