Page 1: ...Installation and Configuration Rev 1 0 0 080508 English Colour box camera electr Day Night DF3000AXS ...

Page 2: ...ritten permission from Dallmeier electronic GmbH Co KG We reserve the right to make technical modifications The manufacturer accepts no liability for damage to property or pecuniary damages arising due to minor defects of the product or documentation e g print or spelling errors and for those not caused by intention or gross negligence of the manufacturer Dallmeier electronic GmbH Co KG Cranachweg...

Page 3: ...signment 13 6 Installation and commissioning 14 6 1 Requirements at the installation site 14 6 2 Attaching the lens 14 6 3 Adjusting the back focus 15 6 4 Installation and commissioning 16 7 Preparing to configure 18 7 1 UTC Remote Box 18 7 2 DMS recorder 19 7 3 PView 19 8 Configuration 20 8 1 Configuration for lenses with manual iris 20 8 2 Presets 21 8 3 Basic functions 22 8 3 1 Camera ID 22 8 3...

Page 4: ...DF3000AXS 4 Dallmeier electronic 9 Appendix 29 9 1 Menu structure 29 9 2 Technical data 30 9 3 Technical drawings 31 9 4 Pin assignment interfaces 32 9 4 1 DC auto iris interface for iris control 32 ...

Page 5: ...and configuration of the device Safety instructions general notes and technical data are additionally provided The target audience is exclusively specially trained and authorized professionals installers 1 3 Convention This document contains various warning words and symbols that indicate potential sources of danger Various symbols and formats are used to maintain the clarity of the document DANGE...

Page 6: ...configurations or incorrect actions NOTE A NOTE offers information on principles special features and efficient procedure as well as general recommendations Expression Expressions in bold and italics generally indicate a control element on the device switches or labels or on its user interface buttons menu entries ...

Page 7: ...Do not make any modifications to the unit neither to the software nor the hardware without consulting Dallmeier electronic Improper modifications can cause malfunctions or damages Dallmeier electronic accepts no liability for damages resulting from unauthorized or improper modifications to the unit Protection against condensation water If the unit is brought from a cold to a warm environment conde...

Page 8: ...owed to get into the device In this case immediately disconnect the unit from the power supply pull out the power plug Please contact the sales partner responsible for your area Measures to be taken in the event of damage and burnt smell If you notice burnt smell or formation of smoke from a unit immediately disconnect it from the power supply pull out the power plug Please contact the sales partn...

Page 9: ...ransportation The goods should only be shipped in their original packaging If the original packaging is no longer available ensure that the packaging used sufficiently protects the unit against damage moisture heat and cold 3 3 Appropriate use The DF3000AXS is a HiRes UWDR Cam_inPIX colour box camera It is designed for indoor use 3 4 Performance features The DF3000AXS is especially characterised b...

Page 10: ...ction available and hence no IR sensitivity NOTE For detailled information please see the chapter Technical data 3 5 Warranty The warranty period is 36 months The terms and conditions valid at the signing of the contract apply 3 6 Certifications The following certifications were in effect at the time this document was produced z CE z FCC z UL z ACA z UVV Kassen z CB ...

Page 11: ... for automatic iris control Video signal controlled lenses are not supported z If the camera or the cables connected to the camera are located near sources of strong radiation the video picture may be distorted z The camera is equipped with automatic gain control AGC In low light the picture may be altered e g noise This is not a camera malfunction z The quality of the video picture depends on the...

Page 12: ...on assignment 5 1 Views A DC auto iris lens not included in the standard scope of delivery B Locking screw for back focus adjustment ring 2 mm Allen screw C tripod socket on top and bottom side D CS lens mount and back focus adjustment ring A B C D Fig 5 1 ...

Page 13: ...ignment E 12V DC input terminal internal inverse polarity protection F RS232 interface for service purposes only G Video output CVBS BNC H Power LED I DC auto iris interface for iris control J Selector 4 way joystick K Enter button G F E H I J K Fig 5 2 ...

Page 14: ...th large scale dust and dirt z with steam or oil vapors e g kitchen z with direct sunlight z with improper ambient temperatures see technical data z near sources of strong radiation i e X rays radio transmitters or magnetic fields z with corrosive surroundings e g gases or salt water 6 2 Attaching the lens M Lens N Lens thread IMPORTANT Possible damage to the sensor The length of the lens thread p...

Page 15: ... image sensor Optimum focus is only possible when the correct distance is set It may be necessary to adjust the back focus in individual cases due to production tolerances of the lens The iris of the lens must be open as wide as possible smallest iris value to adjust the back focus For lenses with automatic iris control you will require a ND filter gray filter to prevent the iris from closing in b...

Page 16: ...s to obtain the best results 8 Tighten the locking screw B 6 4 Installation and commissioning The camera has a tripod socket located on the top and bottom side IMPORTANT Possible damage to the camera caused by inappropriate mounting equipment The length of the tripod screw must not exceed 7 mm IMPORTANT Possible damage to the camera caused by incorrect installation Pay attention to the manufacture...

Page 17: ...T Possible damage to the camera caused by an inadequate po wer supply unit If used in North America you must use a UL certified limited power Class 2 power supply unit 12V DC 0 42A NOTE The camera is provided with internal inverse polarity protection Connect the camera via 12V DC input terminal E to the power supply unit Connect the power supply unit to the mains socket The Power LED H illuminates...

Page 18: ...enu The camera can be configured directly using the Enter button K Selector J or by means of the UTC Remote Box the recorder or PView NOTE There must be no video distributor or signal amplifier between the camera and the UTC Remote Box or recorder or PView NOTE Refer to the separate operator s manuals for the devices or software used 7 1 UTC Remote Box Direct Camera UTC Remote Box CVBS monitor Via...

Page 19: ...a recorder with software version 5 3 1 or higher and a built in FG 11 frame grabber card 7 3 PView Camera Recorder PView station Monitor NOTE This method requires a recorder with software version 5 3 1 or higher and a built in FG 11 frame grabber card using PView version 5 6 0 or higher Fig 7 3 Fig 7 4 ...

Page 20: ... is executed by pressing the Enter button Press the Selector up or down c d to select a menu item from the list Press the Enter button to call up the selected submenu or to execute the command Press the Selector to the left or right e f to change the respective setting value To return from a submenu to the higher order menu select Previous Page and press the Enter button NOTE Please pay attention ...

Page 21: ...f the camera is used z Indoor Shadow Indoor scenes full of contrast The relevant details are in the shadow Detail resolution in the shadowy area is optimized Bright areas of the picture are displayed brighter than normal z Indoor Preset for indoor scenes with medium contrast Details are displayed in high resolution Detail resolution in the bright area is optimized z Fluorescent Use for indoor scen...

Page 22: ...can be used when the automatic white balance produces an unsatisfactory representation of monochrome scenarios This function modifies the metered color temperature 8 3 Basic functions In the Basic Functions area you can make essential settings and specifications for picture display 8 3 1 Camera ID Camera ID allows you to assign a unique name to the camera The maximum length of the ID is 8 characte...

Page 23: ... Linelock function is not supported by the DF3000AXS NOTE Flickerfree Linelock is recommended if cameras without Linelock that are operated with a mains frequency of 50 Hz must be enhanced for scenarios with neon tubes z V Phase After selecting the video level and synchronization you can adjust the V Phase if necessary NOTE The V Phase function is not supported by the DF3000AXS Basic Functions Pre...

Page 24: ... easier read 8 3 6 Day Night Setup The camera has a special setting that allows for detailed shots at night Here the camera can be manually or automatically set to day night mode Night Control Auto is set by default for the DF3000AXS NOTE The Day Night switching is carried out electronically and is not realized by a mechanical ICR function ICR IR Cut Filter Mechanically Removable IR sensitivity is...

Page 25: ...ning the image quality 8 4 1 Progressive Scan z Progressive Scan Off Two fields with differing time index are successively captured and transmitted interlaced scanning Due to the different points in time of capturing within one frame the interlace effect may occur with moving objects Compared to progressive capture rapid movements are displayed more smoothly and in a less jerky manner by twice as ...

Page 26: ...to define the position of the field of view in the example Down has been chosen z Freely defined field of view Select Set and press the Enter button The field of view is displayed in white The position of the field of view can be changed with the Selector Press the Enter button The field of view is displayed in green The field of view can be enlarged with the Selector Press the Enter button The fi...

Page 27: ...ic color reproduction possible regardless of the actual scenario NOTE With light and therefore color temperature modifications no new measurement for white balance is carried out The WB Offset function can be used when the automatic white balance produces an unsatisfactory color representation of monochrome scenarios This function modifies the metered color temperature z ATW With ATW Auto Tracking...

Page 28: ...tion next to Last Changes and press the Enter button If you wish to discard the changes select the Reject option next to Last Changes and press the Enter button z Load Factory Settings To return the configuration to its default settings select the Yes option next to Load Factory Settings and press the Enter button Exit Menu Previous Page Last Changes Reject Load Factory Settings No 3000 Version 1 ...

Page 29: ...ip Off Lens Select DC Color On Day Night Setup Image Functions Previous Page Progressive Scan Off Backlight Off Digital Zoom On White Balance ATW Exit Menu Previous Page Last Changes Reject Load Factory Settings No 3000 Version 1 7 9 Appendix 9 1 Menu structure Presets Previous Page Presets Universal Brightness 0 Gamma Auto Sharpness 1 Saturation 1 WB Offset 0 K ...

Page 30: ...dapter ring Slow Shutter Up to 8x Signal to noise ratio 48 dB Brightness adjustment ALC AE Automatic Manual Backlight compensation BLC Yes with adjustable backlight zone AGC Brightness and gain limit adjustable Gamma correction Automatic Manual Adjustable white balance ATW AWB MWB 2000 K to 11000 K Synchronisation Internal AE Presets 7 Presets Configuration Outlined OSD via UTC commands or at the ...

Page 31: ...DF3000AXS 31 Dallmeier electronic 9 3 Technical drawings Fig 9 1 Fig 9 2 Unit mm ...

Page 32: ...0AXS 32 Dallmeier electronic 9 4 Pin assignment interfaces Fig 9 3 DC auto iris interface for iris control 9 4 1 DC auto iris interface for iris control Pin Signal 1 Control 2 Control 3 Drive 4 Drive 2 3 1 4 ...

Page 33: ... 2006 95 EEC The following company is responsible for this declaration Dallmeier electronic GmbH Co KG Cranachweg 1 D 93051 Regensburg The measurements were carried out in accredited laboratories For the evaluation of above mentioned Council Directives for Electromagnetic Compatibility and for Low Voltage following standards were consulted DIN EN 55022 1998 04 Class B DIN EN 50130 4 2003 09 DIN EN...