Title
Specifications of Lithium Ion battery (Prismatic Type)
page
8/13
11. Exemption from Warrantee
・
SANYO will not be responsible for trouble occurred by handling outside of the precautions
in this specification.
・
SANYO will not be responsible for trouble occurred by matching electric circuit, battery
pack, PDA and charger.
・
SANYO will be exempt from warrantee any defect cells during assembling after acceptance.
12. Other Remarks
・
If there are problems in this specification, SANYO can consider to change specification
after discussion.
・
About the things not covered by this specification, SANYO will have discussion.
・
Do not use this cell for other models or equipment.
13. Standard Charging Method
①
If the cell voltage drops to 0V as a result of storage and the cell is charged at this
condition, the FET on the protection circuit may generate heat.
The charger must have
the pre-charge system.
②
Pre-charge current of charger should be approximately 0.18A. When the battery
voltage becomes 3.0V/cell, standard charge should be started. When the battery
voltage is less than 3.0V/cell even after the set period of timer, charging should be
stopped.
③
Standard charge is 1.88A/cell-4.20V/cell (Constant current-constant voltage).
Charging should be suspended when the time, OCV or current is certain value.
④
The cell could be swelled by continuous charging, especially under the high
temperature atmosphere.
Please consult SANYO regarding the detail for charging method.
File No
UF103450-849
Energy Company, SANYO Electric Co., Ltd.