-36-
Item No.
NAME
Device
XGA
Range Description
PC
Component
Video
HDTV
480p
480i NTSC
PAL
44
NOR_TEMP_FAN2_MIN
46
0-255
FAN2 Control start temp.at High
45
NOR_TEMP_FAN2_MAX
50
0-255
FAN2 Control end temp. at High
46
NOR_VALU_FAN1_MIN
72
0-255
FAN1 Control Min at High (0:0V, 255:25.5V)
47
NOR_VALU_FAN1_MAX
135
0-255
FAN1 Control Max at High
48
NOR_VALU_FAN2_MIN
80
0-255
FAN2 Control Min at High
49
NOR_VALU_FAN2_MAX
130
0-255
FAN2 Control Max at High
50
ECO_TEMP_FAN1_MIN
47
0-255
FAN1 Control start temp.at Normal
51
ECO_TEMP_FAN1_MAX
50
0-255
FAN1 Control end temp. at Normal
52
ECOTEMP_FAN2_MIN
47
0-255
FAN2 Control start temp.at Normal
53
ECO_TEMP_FAN2_MAX
50
0-255
FAN2 Control end temp. at Normal
54
ECO_VALU_FAN1_MIN
55
0-255
FAN1 Control Min at Normal
55
ECO_VALU_FAN1_MAX
115
0-255
FAN1 Control Max at Normal
56
ECO_VALU_FAN2_MIN
62
0-255
FAN2 Control Min at Normal
57
ECO_VALU_FAN2_MAX
86
0-255
FAN2 Control Max at Normal
58
HINOR_TEMP_FAN1_MIN
40
0-255
FAN1 Control start temp.at Highland High
59
HINOR_TEMP_FAN1_MAX
44
0-255
FAN1 Control end temp. at Highland High
60
HINOR_TEMP_FAN2_MIN
40
0-255
FAN2 Control start temp.at Highland High
61
HINOR_TEMP_FAN2_MAX
44
0-255
FAN2 Control end temp. at Highland High
62
HINOR_VALU_FAN1_MIN
135
0-255
FAN1 Control Min at Highland High (0:0V, 255:25.5V)
63
HINOR_VALU_FAN1_MAX
135
0-255
FAN1 Control Max at Highland High
64
HINOR_VALU_FAN2_MIN
130
0-255
FAN2 Control Min at Highland High
65
HINOR_VALU_FAN2_MAX
130
0-255
FAN2 Control Max at Highland High
66
HIECO_TEMP_FAN1_MIN
40
0-255
FAN1 Control start temp.at Highland Normal
67
HIECO_TEMP_FAN1_MAX
44
0-255
FAN1 Control end temp. at Highland Normal
68
HIECOTEMP_FAN2_MIN
40
0-255
FAN2 Control start temp.at Highland Normal
69
HIECO_TEMP_FAN2_MAX
44
0-255
FAN2 Control end temp. at Highland Normal
70
HIECO_VALU_FAN1_MIN
120
0-255
FAN1 Control Min at Highland Normal
71
HIECO_VALU_FAN1_MAX
120
0-255
FAN1 Control Max at Highland Normal
72
HIECO_VALU_FAN2_MIN
91
0-255
FAN2 Control Min at Highland Normal
73
HIECO_VALU_FAN2_MAX
91
0-255
FAN2 Control Max at Highland Normal
74
CLNOR_TEMP_FAN1_MIN
46
0-255
FAN1 Control start temp.at Ceiling High
75
ClNOR_TEMP_FAN1_MAX
50
0-255
FAN1 Control end temp. at Ceiling High
76
CLNOR_TEMP_FAN2_MIN
46
0-255
FAN2 Control start temp.at Ceiling High
77
CLNOR_TEMP_FAN2_MAX
50
0-255
FAN2 Control end temp. at Ceiling High
78
CLNOR_VALU_FAN1_MIN
72
0-255
FAN1 Control Min at Ceiling High (0:0V, 255:25.5V)
79
CLNOR_VALU_FAN1_MAX
135
0-255
FAN1 Control Max at Ceiling High
80
CLNOR_VALU_FAN2_MIN
80
0-255
FAN2 Control Min at Ceiling High
81
CLNOR_VALU_FAN2_MAX
130
0-255
FAN2 Control Max at Ceiling High
82
CLECO_TEMP_FAN1_MIN
47
0-255
FAN1 Control start temp.at Ceiling Normal
83
CLECO_TEMP_FAN1_MAX
50
0-255
FAN1 Control end temp. at Ceiling Normal
84
CLECOTEMP_FAN2_MIN
47
0-255
FAN2 Control start temp.at Ceiling Normal
85
CLECO_TEMP_FAN2_MAX
50
0-255
FAN2 Control end temp. at Ceiling Normal
86
CLECO_VALU_FAN1_MIN
55
0-255
FAN1 Control Min at Ceiling Normal
87
CLECO_VALU_FAN1_MAX
115
0-255
FAN1 Control Max at Ceiling Normal
88
CLECO_VALU_FAN2_MIN
62
0~255 FAN2 Control Min at Ceiling Normal
89
CLECO_VALU_FAN2_MAX
86
0-255
FAN2 Control Max at Ceiling Normal
90
FAN_1_AUTO_ADJ
-
0-1
0: OFF(Manual) 1:ON(Auto)
91
FAN_2_AUTO_ADJ
-
0-1
0: OFF(Manual) 1:ON(Auto)
92
FACTORY_STD_FAN_VOL_MIN
52
0-255
For Factory
93
FACTORY_STD_FAN_VOL_MAX
135
0-255
For Factory
94
FAN1_ADJUST_VOLT_MIN
22
For Factory
✻
Fan ControlAdj.
95
FAN1_ADJUST_VOLT_MAX
203
For Factory
96
FAN2_ADJUST_VOLT_MIN
22
0~255 For Factory
✻
Fan ControlAdj.
97
FAN2_ADJUST_VOLT_MAX
203
For Factory
98
TEMP_ERROR_DETECT_MAX_
TIMES
5
1-9
Detecting times for Temp Error
99
FAN_1_MIN_VOL_LAMP_DIFF
0
0-20
100 FAN_2_MIN_VOL_LAMP_DIFF
0
0-20
101 LAMP_VOL_BORDER_LINE
70
30-90
102 LAMP_VOL
-
0-255
Present Lamp Voltage
103 Dimmer Voltage Change Cycle
3
1-60
Change cycle of voltage at Dimmer
104 Dimmer Avarage Check Period
10
1-30
Measurement time of Dimmer average
105 Dimmer Voltage Change Rate
1
1-50
Voltage change rate ta Dimmer
106 Dimmer Average
-
Dimmer average
107 Last Voltage Difference
-
Last voltage difference
108 Voltage Difference Goal
-
Target voltage difference at Dimmer
109 CoolingSwitch
1
0:Cooling-less 1:Cooling
110 OnStart_Cooling_Start_Temp
38
0-100
Group 200 Auto Calibration
0
Execute Calibration
PW186
0
0 - 255 Auto executiong when value changes
1
Loop Count
PW186
3
1 - 30
Loop times of Auto Calibration
2
OFFSET AREA H START
PW186
25
0 - 4095 Black Level Acquire area H-Start Position
3
OFFSET AREA V START
PW186
500
0 - 4095 Black Level Acquire area V-Start Position
4
GAIN AREA H START
PW186
975
0 - 4095 White Level Acquire area H-Start Position
5
GAIN AREA V START
PW186
500
0 - 4095 White Level Acquire area V-Start Position
6
Image AREA H WIDTH
PW186
13
0 - 4095 Black/White Level Acquire area
7
Image AREA V HIGHT
PW186
9
0 - 4095 Black/White Level Acquire area Height
8
OFFSET target
PW186
1
0 - 127 Target for Black Level Adj.
9
OFFSET torelance
PW186
1
1 - 127 Allowence Range for Black Level Adj
Electrical Adjustments
Summary of Contents for Think GAIA PLC-XE45
Page 28: ... 28 Electrical Adjustments 40 2 0 3 40 40 2 40 40 MAIN BOARD Test Points and Locations ...
Page 53: ... 53 BA7078 Sync Separator IC5301 IC Block Diagrams BA9743 DDC Control IC5651 ...
Page 54: ... 54 IC Block Diagrams L3E6100D D A S H LCD Driver IC501 IC531 IC561 FA5502 P F Control IC621 ...
Page 56: ... 56 IC Block Diagrams M62334 D A IC3571 NJW1141 Audio Control IC5001 ...
Page 57: ... 57 IC Block Diagrams STR Z2156A Power Switching IC631 uPD64012 Video Decoder IC101 ...
Page 87: ...KJ7 XE4500 87 Mechanical Parts List ...
Page 88: ... KJ7AC Feb 2008 DC 300 Printed in Japan SANYO Electric Co Ltd ...