2
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are:
Cooling: Indoor air temperature
27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Heating: Indoor air temperature
20°C D.B.
Outdoor air temperature 7°C D.B. / 6°C W.B.
2. SPECIFICATIONS
2-1. Unit Specifications
Indoor unit
SAP-KRV91EH
Outdoor unit
SAP-CRV91EH
Power Source
220 – 230V Single phase 50Hz
Performance
Cooling
Heating
Capacity
kW
2.80 (0.5 – 4.0)
4.20 (0.5 – 6.0)
BTU/h
9,600 (1,700 – 13,600)
14,330 (1,700 – 20,500)
Air circulation (High)
m
3
/h
550
680
Moisture removal (High)
Liters/h
1.1
—
Electrical Rating
Cooling
Heating
Available voltage range
V
198 – 253
Running amperes
A
3.6 (0.7 – 6.2)
4.6 (0.6 – 7.8)
Power input
W
700 (105 – 1,360)
990 (90 – 1,760)
Power factor
%
85
94
C.O.P.
W/W
4.0
4.2
Compressor locked rotor amperes
A
15
Features
Controls / Temperature control
Microprocessor / I.C. thermostat
Control unit
Wireless remote control unit
Timer
ON / OFF 24 hours & Daily program, 1-hour OFF
Fan speeds
Indoor / Outdoor
3 and Auto / Auto (Variable)
Airflow direction (Indoor)
Horizontal
Auto
Vertical
Auto
Air filter
Washable, Anti-Mold
Compressor
Rotary (Hermetic)
Refrigerant / Amount charged at shipment
g
R410A / 1,290
Refrigerant control
Electric Expansion Valve
Operation sound
Indoor: Hi / Me / Lo
dB-A
37 / 35 / 31
42 / 37 / 32
Outdoor: Hi
dB-A
43
44
Refrigerant tubing connections
Flare type
Max allowable tubing length at shipment
m
7.5
Refrigerant
Narrow tube
mm (in.)
6.35 (1/4)
tube diameter
Wide tube
mm (in.)
9.52 (3/8)
Refrigerant tube kit / Accessories
Optional / Air Clean Filter
Voltage Rating
230V
Dimensions & Weight
Indoor Unit
Outdoor Unit
Unit dimensions
Height
mm
285
620
Width
mm
805
700
Depth
mm
189
260
Package dimensions
Height
mm
264
681
Width
mm
865
835
Depth
mm
349
364
Weight
Net
kg
9.0
36.0
Shipping
kg
12.0
38.0
Shipping volume
m
3
0.08
0.207