32
8. MAINTENANCE
8-1. Address Setting of the Remote
Control Unit
The address can be set in order to prevent interfer-
ence between remote controllers when two Sanyo
indoor units are installed near each other. The address
is normally set to “A.” To set a different address, it is
necessary to change the address on the second
remote controller.
Once changed, you cannot restore the original
address setting of the air conditioner.
(1) Switch on the power source.
(2) Break the address-setting tab marked “A” on the
second remote controller to change the address
(Fig. 13). When the tab is removed, the address is
automatically set to B (Fig. 14).
(3) Press and hold the remote controller QUIET but-
ton and 1 HR TIMER button. At the same time,
press the ACL (reset) button. Use a thin object
such as the tip of a pen to press the ACL button.
When this has been done, “oP-1” (test run)
appears, blinking, in the remote controller clock
display area.
(4) Each time the 1 HR TIMER button is pressed, the
display changes as shown below. Press this but-
ton 2 times to change the display to “oP-7”
(address setting). (Fig. 15)
(5) “oP-7” has now been selected for address setting.
(6) Press the ON/OFF operation button on the remote
controller. (Fig. 15) Check that the “beep” signal-
received sound is heard from the second indoor
unit (approximately 5 times). The sound you hear
is the signal that the remote controller address
has been changed.
(7) Finally press the remote controller ACL (reset)
button to cancel the blinking “oP-7” display.
(Fig. 15)
Changing of the second remote controller address is
now completed.
Test run mode
Self-diagnostic mode
Address setting mode
NOTE
Fig. 13
Fig. 14
Fig. 15
Tab
ACL button
ON•/OFF•
1HR.
UIET
MODE
TEMP.
TIMER
CANCEL
SENSOR
ADR
ACL
24H
12H
F
CLOCK
NIGHT SETBACK
FAN SPEED
HIGH POWER
FLAP
AIR CONDITIONER
1HR.
TIMER
ON/OFF
operation
ACL
(Reset)
QUIET
button
button
button
button