41
Single-room operation
Indoor unit
Indoor Unit Capacity (kW)
Conbination
Room A
Room B
Room C
Total Performance
Power Input (W)
Current (A)
Min. - Max.
Min. - Max.
2.8
Cooling
2.8
2.8
960
4.5
0.7
-
3.2
330
-
1,080
3.6
Cooling
3.6
3.6
1,190
5.6
0.8
-
3.6
360
-
1,190
5
Cooling
5.0
5.0
1,660
7.9
1.1
-
5.8
450
-
1,900
Two-room operation
Indoor unit
Indoor Unit Capacity (kW)
Conbination
Room A
Room B
Room C
Total Performance
Power Input (W)
Current (A)
Min. - Max.
Min. - Max.
2.8+2.8
Cooling
2.80
2.80
5.6
1,790
8.5
1.4
-
6.5
540
-
2,060
2.8+3.6
Cooling
2.45
3.15
5.6
1,790
8.5
1.4
-
6.5
540
-
2,060
3.6+3.6
Cooling
2.80
2.80
5.6
1,790
8.5
1.4
-
6.5
540
-
2,060
2.8+5.0
Cooling
2.00
3.60
5.6
2,030
9.6
1.2
-
7.0
480
-
2,270
3.6+5.0
Cooling
2.35
3.25
5.6
2,030
9.6
1.2
-
7.0
480
-
2,270
Outdoor Unit
SAP – CMRV1923GJ
2.8:
SAP-#MRV93GJ
3.6:
SAP-#MRV123GJ
5.0:
SAP-#MRV183GJ
NOTE
2-Room Outdoor Unit Combination Table
Indoor Unit
Combination
2-room operation
Single-room operation
Indoor Unit
Combination