21
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.36
0.49
7.65
8.5
Power Input
kW
0.074
0.112
1.694
1.88
Full Load Conditions Running Amps.
A
0.36
0.49
9.95
10.8
Power Input
kW
0.074
0.112
2.204
2.39
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit
SAP – K91GA (
✕
2)
Outdoor Unit
SAP – CM1821GA
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.18
0.49
4.13
4.8
Power Input
kW
0.037
0.112
0.851
1.00
Full Load Conditions Running Amps.
A
0.18
0.49
5.03
5.7
Power Input
kW
0.037
0.112
1.041
1.19
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit
SAP – K91GJA (
✕
1)
Outdoor Unit
SAP – CM1821GA