2-3. Other Component Specifications
5
Fuse
Cartridge type
Rating / Size
250V, 20A / ø6.4 x 30mm
Power Relay
G7L-2A-TUB
Coil rating
AC 200 – 240V, 50/60Hz
Coil resistance
k
Ω
(at 23°C)
( 21 ± 15% )
Contact rating
AC 220V, 25A
Thermistor (Air sensor)
PBC – 41E – S14
Resistance
k
Ω
– 20°C 40.1± 5%
20°C
6.5 ± 5%
– 10°C 24.4 ± 5%
30°C
4.4 ± 5%
0°C 15.3 ± 5%
40°C
3.0 ± 5%
10°C
9.9 ± 5%
50°C
2.1± 5%
Thermistor (Coil sensor)
PBC – 41E – S14
Resistance
k
Ω
– 20°C 40.1± 5%
20°C
6.5 ± 5%
– 10°C 24.4 ± 5%
30°C
4.4 ± 5%
0°C 15.3 ± 5%
40°C
3.0 ± 5%
10°C
9.9 ± 5%
50°C
2.1± 5%
4-way Valve (Solenoid coil)
CHV-01AJ504D (Coil), CHV-0301 (Valve)
Coil rating
AC 220–240V, 50Hz, 6W
Outdoor Unit
SAP – C301AH
Thermistor (Room sensor)
DTN-TKS128B
Resistance
k
Ω
25°C
5.0 ± 3%
Thermistor (Coil sensor)
DTN-TKS131B
Resistance
k
Ω
0°C
15.0 ± 2%
Transformer (TR)
ATR-J105-I
Rating
Primary
AC 230V, 50 / 60 Hz
Secondary
19V, 0.526A
Capacity
10VA
Coil resistance
Ω
(at 21°C)
Primary (WHT – WHT):
205 ± 10%
Secondary (BRN – BRN):
2.0 ± 10%
Thermal cut-off temp.
150°C
Indoor Unit
SAP – K301AH