13
6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor Unit
SAP – K301AH
Outdoor Unit
SAP – C301AH
COOLING
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
240V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.330
0.660
12.01
13.0
Power Input
kW
0.072
0.146
2.882
3.10
Full Load Conditions Running Amps.
A
0.330
0.660
14.51
15.5
Power Input
kW
0.072
0.146
3.472
3.69
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
HEATING
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
240V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.330
0.660
11.01
12.0
Power Input
kW
0.072
0.146
2.632
2.85
Full Load Conditions Running Amps.
A
0.330
0.660
14.91
15.9
Power Input
kW
0.072
0.146
3.562
3.78
Rating Conditions
: Indoor Air Temperature 20°C D.B.
Outdoor Air Temperature 7°C D.B. / 6°C W.B.
Full Load Conditions : Indoor Air Temperature 27°C D.B.
Outdoor Air Temperature 24°CD.B. / 18°CW.B.