-56-
●
Circuit Adjustment
CAUTION: The each circuit has been made by the fine adjustment at factory. Do not attempt to adjust the following
adjustments except requiring the readjustments in servicing otherwise it may cause loss of performance and
product safety.
[Adjustment Condition]
●
Input signal
Computer signal ............................. 0.7Vp-p/75Ω terminated, 16 steps gray
scale pattern, 1 line dot pattern, 100% and
50% whole white pattern (720p format)
Component Video signal ............. 0.7Vp-p/75Ω terminated, 16 steps gray
scale pattern (480i, 480p, 720p and 1080i
format), 100% and 50% whole white pat-
tern (480p format)
Video signal ..................................... 1.0Vp-p/75Ω terminated, 16 steps gray
scale pattern (NTSC composite video sig-
nal)
●
Image level selection........................ “Dynamic” mode unless otherwise noted.
Note:
* Please refer to “Service Adjustment Menu Operation” for entering to the
service mode and adjusting the service data.
White 100%
Black 100%
白
100%
黒
100%
16 steps gray scale pattern
Equipment
Digital voltmeter
1. Enter the service mode.
2. Change data values of each test points to adjust the fan
minimum output voltage.
Item no. Fan Location Test Point Adjustment value
250 - 8
FN901
TPFAN1
3.5
±0.05Vdc
250 - 9
FN902
TPFAN2
3.5
±0.05Vdc
250 - 10 FN903
TPFAN3
3.5
±0.05Vdc
250 - 11 FN904
TPFAN4
3.5
±0.05Vdc
GND
TE6601
Note:
The location of each fan is refer to the parts list.
FN905 is non adjustment.
1. Fan minimum voltage adjustment
WARNING : USE UV RADIATION EYE AND SKIN PROTECTION
DURING SERVICING
CAUTION: To prevent suffer of UV radiation, those adjustments
must be completed within 25 minutes.
Equipment
Digital voltmeter
1. Enter the service mode.
2. Change data values of each test points to adjust the fan
minimum output voltage.
Item no. Fan Location Test Point Adjustment value
250 - 12 FN901
TPFAN1
13.8
±0.05Vdc
250 - 13 FN902
TPFAN2
13.8
±0.05Vdc
250 - 14 FN903
TPFAN3
13.8
±0.05Vdc
250 - 15 FN904
TPFAN4
13.8
±0.05Vdc
GND
TE6601
Note:
The location of each fan is refer to the parts list.
FN905 is non adjustment.
2. Fan max voltage adjustment
Electrical Adjustments
Summary of Contents for PLV-Z2000
Page 41: ...25 Condensor lenses removal 27 Mirrores removal 41 Optical disassemblies ...
Page 114: ...108 111 111 112 108 120 119 106 108 110 105 104 121 Mechanical Parts List 114 114 MD4 Z200000 ...
Page 117: ... 117 ...
Page 118: ... 118 118 ...
Page 119: ... 119 119 ...
Page 120: ...SM5110894 00 PLV Z2000 Nov 2007 DC 350 Printed in japan ...