-7-
Turn off the projector, and unplug the AC power cord
from the AC outlet.
Turn the projector over and remove the filters by pulling
the latches upward.
1
2
Filters prevents dust from accumulating on the optical elements inside the projector. Should the filters become
clogged with dust particles, it will reduce cooling fans’ effectiveness and may result in internal heat buildup
and adversely affect the life of the projector. If a “Filter warning” icon appears on the screen, clean the filters
immediately. Clean the filter by following the steps below.
Gently clean the filters by using a brush or rinse them
softly.
3
When rinsing the filters, dry them well. Replace the
filters properly. Make sure that the filters are fully
inserted to the projector.
4
cAutIoN
Do not operate the projector with the filters
removed. Dust may accumulate on the optical
elements degrading picture quality.
Do not put anything into the air vents. Doing so
may result in malfunction of the projector.
recoMMeNdAtIoN
We recommend avoiding dusty/smoky environments when
you operate the projector. Usage in these environments may
cause poor image quality.
When using the projector under dusty or smoky conditions,
dust may accumulate on a lens, LCD panels, or optical
elements inside the projector degrading the quality of a
projected image. When the symptoms above are noticed,
contact your authorized dealer or service station for proper
cleaning.
✔
Note
:
• When reinserting this filter, be sure that the slit
part is facing the outer side.
Be sure to reset the Filter counter after cleaning or replacing the filter.
Press the MENU button to display the On-Screen Menu.
Use the Point
7 8
buttons to move the red frame point-
er to the Setting Menu icon.
Use the Point
ed
buttons to move the red frame point-
er to Filter counter and then press the SELECT button. A
dialog box appears showing the total accumulated time
of the filter use, a timer setting option, and the reset op-
tion. Select Reset and the “Filter counter Reset?” ap-
pears. Select [Yes] to continue.
1
2
Resetting the Filter Counter
Filter counter
Another confirmation dialog box appears, select [Yes] to
reset the Filter counter.
3
Cleaning the Filter
Maintenance
Filters
Pull up and remove.
Select Reset and the “Filter
counter Reset?” appears.
Select [Yes],
then another
confirmation
box appears.
Select [Yes] again to reset
the Filter counter.
On 1
Summary of Contents for PLC-XU115
Page 65: ... 65 IC Block Diagrams FA7701 DDC Control IC5751 AN5870 Signal Switch IC5201 ...
Page 66: ... 66 IC Block Diagrams FA7711 DC DC Converter IC5801 FA5502 P F Control IC601 ...
Page 69: ... 69 IC Block Diagrams LM4889 Audio Output IC5031 NJW1156 Audio Control IC5001 ...
Page 70: ... 70 IC Block Diagrams PW190 Scaler IC301 STR Z2156 Power OSC IC651 ...
Page 71: ... 71 IC Block Diagrams TE7783 Parallel I O Expander IC1802 ...
Page 108: ... KF3AC April 2008 DC 300 Printed in Japan SANYO Electric Co Ltd ...
Page 128: ...A18 PCB_KF3AC NO DATA ...