WARNING:
The chassis of this projector is isolated (COLD) from AC line by using the converter transformer. Primary side
of the converter and lamp power supply unit circuit is connected to the AC line and it is hot, which hot circuit is
identified with the line (
) in the schematic diagram. For continued product safety and protection of per-
sonnel injury, servicing should be made with qualified personnel.
The following precautions must be observed.
Safety Precautions
1: An isolation transformer should be connected in
the power line between the projector and the AC line
before any service is performed on the projector.
: Comply with all caution and safety-related notes
provided on the cabinet back, cabinet bottom, inside
the cabinet or on the chassis.
3: When replacing a chassis in the cabinet, always
be certain that all the protective devices are
installed properly, such as, control knobs, adjust-
ment covers or shields, barriers, etc.
DO NOT OPERATE THIS PROJECTOR WITHOUT
THE PROTECTIVE SHIELD IN POSITION AND PR
OPERLY SECURED.
4: Before replacing the cabinet cover, thoroughly
inspect the inside of the cabinet to see that no stray
parts or tools have been left inside.
Before returning any projector to the customer, the
service personnel must be sure it is completely safe
to operate without danger of electric shock.
Service Personnel Warning
Eye damage may result from directly viewing the light produced by the Lamp used in this equipment. Always
turn off Lamp before opening cover. The Ultraviolet radiation eye protection required during this servicing.
Never turn the power on without the lamp to avoid electric-shock or damage of the devices since the stabilizer
generates high voltages (15kV - 5kV) at its starts.
Since the lamp is very high temperature during units operation replacement of the lamp should be done at least
45 minutes after the power has been turned off, to allow the lamp cool-off.
Product Safety Notice
Product safety should be considered when a component replacement is made in any area of the projector.
Components indicated by mark
!
in the parts list and the schematic diagram designate components in which
safety can be of special significance. It is, therefore, particularly recommended that the replacement of there
parts must be made by exactly the same parts.
do Not AtteMPt to SerVIcING tHe reMote coNtroL uNIt.
Laser Beam may be leaked out when in disassemble the Unit. As the Laser Beam
used in this Remote control unit is harmful to the eyes.
Battery Replacement Notice
caution
Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type
recommended by the manufacturer. Dispose of used batteries according to the manufacture’s instructions.
Replace Battery With SANYO Electric Co., Ltd., Part No. 645 089 8587 Only. Use of Another Battery May
Present A Risk Of Fire or Explosion.
Summary of Contents for PLC-XU111
Page 62: ... 62 IC Block Diagrams BA7078 Sync Separator IC5301 AN5870 Signal Switch IC5201 ...
Page 63: ... 63 IC Block Diagrams FA5502 P F Control IC601 BA9743 DDC Control IC5751 ...
Page 64: ... 64 IC Block Diagrams HIN202EIB RS 232C Driver IC3801 FA7711 DC DC Converter IC5801 ...
Page 66: ... 66 IC Block Diagrams L3E01060 Level Shift IC2501 IC2531 IC2561 LM4889 Audio Output IC5031 ...
Page 67: ... 67 IC Block Diagrams NJW1141 Audio Control IC5001 M62334 DAC IC3501 ...
Page 68: ... 68 IC Block Diagrams PW190 Scaler IC301 STR Z2156 Power OSC IC651 ...
Page 69: ... 69 IC Block Diagrams TE7783 Parallel I O Expander IC1802 ...