-73-
Electrical Adjustment
Group/
Item
Item Name
Function
Initial
Range
Note
Group 253 Fan Tem Error Setting (Memorized)
Normal
Ceiling
L1
L2
0 Temp A Warning (High)
Temp. A to judge the Temp Error at High
(Room)
43
43
43
43
30-100
L1
160°
200°
20°
340°
(-20°)
(-160°)
L2
Normal
Ceiling
Off
L1
L2
Off
Normal
Up
Down
On
Ceiling
Up
Down
Slant
Ceiling
Definition of Slant
Off
-20° ~ 20°
L1
20° ~ 160°
L2
-20° ~ -160°
1 Temp B Warning (High)
Temp. A to judge the Temp Error at High
(Lamp)
60
60
60
60
30-100
2 Temp C Warning (High)
Temp. A to judge the Temp Error at High
(Panel)
48
48
48
48
30-100
3 Temp B-A Warning (High)
Temp. B-A to judge the Temp Error at High
(Clogging Det.)
100
100
100
100
0-100
4 Temp C-A Warning (High)
Temp. C-A to judge the Temp Error at High
(Clogging Det.)
100
100
100
100
0-100
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at Normal
(Room)
43
43
43
43
30-100
6 Temp B Warning (Normal)
Temp. A to judge the Temp Error at Normal
(Lamp)
61
61
61
61
30-100
7 Temp C Warning (Normal)
Temp. A to judge the Temp Error at Normal
(Panel)
48
48
48
48
30-100
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at Normal
(Clogging Det.)
100
100
100
100
0-100
9 Temp C-A Warning (Normal)
Temp. C-A to judge the Temp Error at Normal
(Clogging Det.)
100
100
100
100
0-100
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error at Eco (Room)
43
43
43
43
30-100
11 Temp B Warning (Eco)
Temp. A to judge the Temp Error at Eco (Lamp)
62
62
62
62
30-100
12 Temp C Warning (Eco)
Temp. A to judge the Temp Error at Eco (Panel)
48
48
48
48
30-100
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at Normal
(Clogging Det.)
100
100
100
100
0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at Normal
(Clogging Det.)
100
100
100
100
0-100
15 Temp A Warning Offset (Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at the
below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
10
0-100
16 Temp B Warning Offset (Temp)
11
0-100
17 Temp C Warning Offset (Temp)
13
0-100
18 Temp B-A Warning Offset (Temp)
11
0-100
19 Temp C-A Warning Offset (Temp)
13
0-100
20 Temp A Warning Offset (Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X minute at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
30
0-40
21 Temp B Warning Offset (Time)
15
0-40
22 Temp C Warning Offset (Time)
15
0-40
23 Temp B-A Warning Offset (Time)
15
0-40
24 Temp C-A Warning Offset (Time)
15
0-40
Group 254 Fan Control Range Setting (Temp./REV)
Normal
Ceiling
L1
L2
0 High Fan Control Min Temp
Temp Senser Control Start/End Tem.p at High
26
26
26
26
20-100
L1
160°
200°
20°
340°
(-20°)
(-160°)
L2
Normal
Ceiling
Off
L1
L2
Off
Normal
Up
Down
On
Ceiling
Up
Down
Slant
Ceiling
Definition of Slant
Off
-20° ~ 20°
L1
20° ~ 160°
L2
-20° ~ -160°
1 High Fan Control Max Temp
35
35
35
35
20-100
2 High Fan1 Min
Fan Operation REV(Min/Max) setting at High
(rpm)
2775
2775
2775
2775
0000-9990
3 High Fan1 Max
2975
2975
2975
2975
0000-9990
4 High Fan2 Min
1800
1800
1800
1800
0000-9990
5 High Fan2 Max
2555
2555
2555
2555
0000-9990
6 High Fan3 Min
4700
4700
5900
5900
0000-9990
7 High Fan3 Max
4800
4800
6100
6100
0000-9990
8 High Fan4 Min
3120
3120
3120
3120
0000-9990
9 High Fan4 Max
5865
5865
5865
5865
0000-9990
10 Normal Fan Control Min Temp
Temp Senser Control Start/End Tem.p at
Normal
26
26
26
26
20-100
11 Normal Fan Control Max Temp
35
35
35
35
20-100
12 Normal Fan1 Min
Fan Operation REV(Min/Max) setting at
Normal (rpm)
2495
2495
2495
2495
0000-9990
13 Normal Fan1 Max
2795
2795
2795
2795
0000-9990
14 Normal Fan2 Min
1625
1625
1625
1625
0000-9990
15 Normal Fan2 Max
2245
2245
2245
2245
0000-9990
16 Normal Fan3 Min
3650
3650
4850
4850
0000-9990
17 Normal Fan3 Max
3725
3725
5000
5000
0000-9990
18 Normal Fan4 Min
2605
2605
2605
2605
0000-9990
19 Normal Fan4 Max
5275
5275
5275
5275
0000-9990
20 Eco Fan Control Min Temp
Temp Senser Control Start/End Tem.p at Eco
26
26
26
26
20-100
21 Eco Fan Control Max Temp
35
35
35
35
20-100
22 Eco Fan1 Min
Fan Operation REV(Min/Max) setting at Eco
(rpm)
2210
2210
2210
2210
0000-9990
23 Eco Fan1 Max
2610
2610
2610
2610
0000-9990
24 Eco Fan2 Min
1450
1450
1450
1450
0000-9990
25 Eco Fan2 Max
1935
1935
1935
1935
0000-9990
26 Eco Fan3 Min
2600
2600
3800
3800
0000-9990
27 Eco Fan3 Max
2650
2650
3900
3900
0000-9990
28 Eco Fan4 Min
2090
2090
2090
2090
0000-9990
29 Eco Fan4 Max
4685
4685
4685
4685
0000-9990
Summary of Contents for PLC-XT35
Page 102: ... 102 IC Block Diagrams BA7078 Sync Seperator IC5321 FA7701V Switching Controller IC5641 ...
Page 105: ... 105 IC Block Diagrams LM4889 Audio Output IC5121 NJW1141 Audio Control IC5001 ...
Page 107: ... 107 IC Block Diagrams CXA2229 Video SW Sync IC101 CXD3815 Video Decoder IC3101 ...
Page 108: ... 108 IC Block Diagrams THS7347IPHPR PC1 PC2 SW IC5201 ...
Page 139: ... 139 Mechanical Parts List KP3 XT3500 KP3 XT35L00 ...
Page 140: ... KP3A Nov 2007 DC 350 Printed in Japan SANYO Electric Co Ltd ...