-7-
Maintenance
Turn off the projector, and unplug the AC power cord
from the AC outlet.
Remove the front air filter by pulling the latch
horizontally.
Remove the back air filter by pulling the latch
horizontally and then remove it leftward.
1
2
Filter prevents dust from accumulating on the optical elements inside the projector. Should the filters become
clogged with dust particles, it will reduce cooling fans’ effectiveness and may result in internal heat buildup
and adversely affect the life of the projector. If a “Filter warning” icon appears on the screen, clean the filters
immediately. Clean the filters by following the steps below.
Clean the air filters with a brush or rinse them softly.
3
When cleaning the air filters by rinsing, dry it well.
Replace the air filters properly. Make sure that the air
filters are fully inserted.
4
cAutIoN
Do not operate the projector with the filters
removed. Dust may accumulate on the optical
elements degrading picture quality.
Do not put anything into the air vents. Doing so
may result in malfunction of the projector.
recoMMeNdAtIoN
We recommend avoiding dusty/smoky environments
when you operate the projector. usage in these
environments may cause poor image quality.
When using the projector under dusty or smoky conditions,
dust may accumulate on a lens, LCD panels, or optical
elements inside the projector degrading the quality of a
projected image. When the symptoms above are noticed,
contact your authorized dealer or service station for proper
cleaning.
Be sure to reset the Filter counter after cleaning or replacing
the filters.
Press the MENU button to display the On-Screen
Menu. Use the Point buttons to select
Setting
and
then press the Point
or SELECT
button.
Use the Point buttons to select
Filter counter
and
then press the Point
or the
SELECT button. Use the
Point buttons to select
Filter counter reset
and then
press the SELECT button.
Filter counter reset?
appears. Select
Yes
to continue.
1
2
resetting the Filter counter
Filter counter
Filter counter
reset?
appears.
Select
Yes
, then
another confirmation
box appears.
Select
Yes
again
to reset the Filter
counter.
Another confirmation dialog box appears, select
Yes
to
reset the Filter counter.
3
cleaning the Filters
Air filter (front)
Pull horizontally and remove.
Air filter (back)
Pull horizontally and then remove it leftward.
4
Note
:
Please be sure to
fit this edge when
inserting this filter.
Summary of Contents for PLC-XD2200
Page 67: ... 67 FA5550NG P F Control IC621 LC87F2G08A5AN6 UART IC9885 IC Block Diagrams ...
Page 70: ... 70 IC Block Diagrams PW190 Scaler IC301 MR4010 Power OSC IC631 ...
Page 71: ... 71 IC Block Diagrams PIC18F67J60 LAN CONTROL IC8801 FA7703 DC DC Converter IC7811 ...
Page 98: ... KR8AC KS8AC April 2010 DC 200 Printed in Japan SANYO Electric Co Ltd ...
Page 114: ...A14 PCB_KR8AC NO DATA ...