-47-
Electrical Adjustments
Group/
Item
Item Name
Function
Initial
range Note
6 Not used
-
Plc-xd2600
Group
253
Fan tem error Setting (Memorized)
Normal Ceiling HiLand-
Normal
HiLand-
Ceiling
0 Temp A Warning (High)
45
45
44
44
-
1 Temp B Warning (High)
55
54
54
54
-
2 Temp C Warning (High)
59
59
58
58
-
Temp B-A Warning(High)
100
100
100
100
-
4 Temp C-A Warning(High)
100
100
100
100
-
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at
Normal (Room)
45
45
44
44
0-100
6 Temp B Warning (Normal)
Temp. B to judge the Temp Error at
Normal (Panel)
55
54
5
5
0-100
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at
Normal (Lamp)
58
58
57
57
0-100
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
9 Temp C-A Warning(Normal)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error at Eco
(Room)
44
44
4
4
0-100
11 Temp B Warning (Eco)
Temp. B to judge the Temp Error at
Eco(Panel)
54
5
52
52
0-100
12 Temp C Warning (Eco)
Temp. C to judge the Temp Error at
Eco(Panel)
57
56
55
55
0-100
1 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
15 Temp A Warning Offset
(Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5
0-100
16 Temp B Warning Offset
(Temp)
5
0-100
17 Temp C Warning Offset
(Temp)
5
0-100
18 Temp B-A Warning Offset
(Temp)
0
0-100
19 Temp C-A Warning Offset
(Temp)
0
0-100
20 Temp A Warning Offset
(Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X min-
ute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
0-100
21 Temp B Warning Offset
(Time)
0-100
22 Temp C Warning Offset
(Time)
0-100
2 Temp B-A Warning Offset
(Time)
0-100
24 Temp C-A Warning Offset
(Time)
0-100
Plc-xd2600
Group
254
Fan control range Setting (temp./Voltage)
Normal Ceiling HiLand-
Normal
HiLand-
Ceiling
0 High Fan Control Min Temp
2
1
2
-
1 High Fan Control Max Temp
41
41
8
8
-
2 High Fan1 Min
78
80
98
100
-
High Fan1 Max
15
15
15
15
-
4 High Fan2 Min
75
85
100
110
-
5 High Fan2 Max
90
95
125
10
-
6 High Fan Min
75
80
100
105
-
7 High Fan Max
100
105
110
115
-
10 Normal Fan Control Min Temp
Temp Senser Control Start/End Tem.p
at Normal
2
2
20-100
11 Normal Fan Control Max
Temp
40
40
8
8
20-100
12 Normal Fan1 Min
Fan voltage value at Normal (unit: 0.1V)
68
75
95
100
0-255
1 Normal Fan1 Max
15
15
15
15
0-255
14 Normal Fan2 Min
7
85
100
11
0-255
15 Normal Fan2 Max
96
101
124
129
0-255
16 Normal Fan Min
75
80
100
105
0-255
17 Normal Fan Max
15
15
15
15
0-255
20 Eco Fan Control Min Temp
Temp Senser Control Start/End Tem.p
at Eco
2
2
2
1
20-100
21 Eco Fan Control Max Temp
40
9
8
7
20-100
22 Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
52
60
75
80
0-255
2 Eco Fan1 Max
120
120
125
125
0-255
24 Eco Fan2 Min
45
45
60
60
0-255
Summary of Contents for PLC-XD2200
Page 67: ... 67 FA5550NG P F Control IC621 LC87F2G08A5AN6 UART IC9885 IC Block Diagrams ...
Page 70: ... 70 IC Block Diagrams PW190 Scaler IC301 MR4010 Power OSC IC631 ...
Page 71: ... 71 IC Block Diagrams PIC18F67J60 LAN CONTROL IC8801 FA7703 DC DC Converter IC7811 ...
Page 98: ... KR8AC KS8AC April 2010 DC 200 Printed in Japan SANYO Electric Co Ltd ...
Page 114: ...A14 PCB_KR8AC NO DATA ...