background image

1

PJ NETWORK MANAGER

OWNER'S MANUAL

When happens the alert on the target

If the abnormality or connection error happens on the target, PJ Network Manager indi-
cates target name, icon and status column item with red color to let you know the abnor-
mality.

0

  When PJ Network Manager cannot acquire the MIB information of the target equipment, it indi-

cates as Connection Error.

0

  The interval of target monitoring is according to the setting of 

Monitoring interval

 on 

System 

default setting

 from 

System

 menu. 

(

+

p.17)

When happens the trap event on the target

During the target monitoring, if the predefined event (trap) happens on the target equip-
ment, the target sends the trap information to PJ Network Manager. This trap information is 
displayed on the status list immediately.
The notification of the trap information is set up in the SNMP setting items of the target 
equipment. Projector has items such as "When PJ lamp is off", "When the life span of lamp 
is reached", "When internal PJ power circuit is failed" etc. For further trap information, refer 
to SNMP trap information in the separated network owner's manual.

What's Trap

Trap is the event predefined by the SNMP agent. If the predefined event ( "When PJ lamp is 
off", "When internal PJ power circuit is failed" etc. ) happens, target sends trap information 
to the SNMP manager.

When happens the alert on the target

Summary of Contents for PLC-XC56 - 3100

Page 1: ...Windows compliant but non Mac compliant Read this manual thoroughly to operate the PJ Network Manager software First read the owner s manual of the projector to understand the basic oper ation of the projector and the safety instructions The safety instructions in the owner s manuals should be followed strictly Owner s Manual ...

Page 2: ...et 13 When happens the trap event on the target 13 What s Trap 13 Stopping monitoring the target 14 Displaying all the status information of the target 14 Setting the target group 14 Setting up the password of Telnet 15 Setting commands batch processing for multiple targets 15 Setting timer for targets 16 Setting up default setting 17 Customizing the status list 19 Viewing the alert information 22...

Page 3: ...nected to the network SNMP realizes the management function by reading and changing the management infor mation called MIB with SNMP protocol between the manager management equipment and agent controlled equipment which are connected with TCP IP network Trademarks Microsoft Windows Windows 2000 Windows XP Windows Vista are registered trademarks of Microsoft Corporation Macintosh is a registered tr...

Page 4: ...ws Vista 32bit version Limited condition The number of agents monitored is up to 200 Chapter 1 Introducing Expression Abbreviation The OS of the computer and the Web browser described in this manual is Windows XP Professional and Internet Explorer 6 0 In case of another OS or Web browser some instruc tion procedures may differ from the actual operation depending on your computer envi ronment Use o...

Page 5: ... PJ NETWORK MANAGER OWNER S MANUAL Chapter 2 Set up 2 ...

Page 6: ...wizards As the Software License Agreement will appear read contents carefully and click Yes button if you agree with the license agree ment to proceed with installing Note To install the software into the computer with Windows 2000 Windows XP or Windows Vista you should logon as administrator Before installation make sure that the other applications are closed otherwise proper installation cannot ...

Page 7: ... PJ NETWORK MANAGER OWNER S MANUAL Chapter 3 Basic Operation 3 ...

Page 8: ...ger and explaining the command selected with cursor Status list Indicates the status of targets monitoring When some errors are detected the target name icon and error items are indicated with red Status column Column of status list Polling times indication Indicates the times of polling during the monitoring Event indication Indicates the event ALERT TRAP SYSERR when the event happened Name of st...

Page 9: ...of the selected target Telnet setting Sets up the password of telnet Commands batch processing Sets commands batch processing for multiple selected targets Timer setting Sets up the timer for the selected target System Target batch registration Imports target information defined with the external file System default setting Sets up the default setting monitoring information e mail informa tion Col...

Page 10: ...mand history display Displays all of the command history 0 To switch the tool bar display on or off select Tool bar from Display menu New Save Target display Event log display Target monitoring Start Stop Open Alert display Icon display for the target Displays icon according to the target condition Icon Condition Flat display type Projector type Normal Abnormal condition One of the abnormalities A...

Page 11: ...it the contents then click OK button 0 The system information cannot be edited 0 Target editing can be executed by selecting Target editing from Target menu Deletion of the target 1Select a target name to delete on the status list with right click 2 Select Target deletion on the popup menu The confirmation dialog will appear and click Yes button to execute deleting 0 Target deletion can be execute...

Page 12: ...Edit button Another setting window appears 4 Enter the threshold value of selected item and then click OK button The setting window will dis appear 5 Set up warning value for remaining items if avail able and then click OK button The setting win dow will disappear 0 To disable the warning value clear Warning time check box 0 When selecting multiple targets the value set to the lowest target on the...

Page 13: ...nitoring if the predefined event trap happens on the target equip ment the target sends the trap information to PJ Network Manager This trap information is displayed on the status list immediately The notification of the trap information is set up in the SNMP setting items of the target equipment Projector has items such as When PJ lamp is off When the life span of lamp is reached When internal PJ...

Page 14: ... To stop monitoring the target click button again on the tool bar 0 The projectors setting different network passwords cannot be set to the same group It is necessary for the projectors in the same group to set to the same password 0 The above procedure can perform by selecting Target display from Display menu Setting the target group The target group can be set up by the procedure below When you ...

Page 15: ...word of Telnet 0 The initial setting is 0000 Setting commands batch processing for multiple targets The commands batch processing for multiple targets can be set up by the procedure below 1 Select a target belonging to the batch processing group which you want to set and select Commands batch processing from Target menu Commands batch processing dialog box will appear as the below figure 2 Select ...

Page 16: ... the Fan control Chooses the running speed of cooling fans Setting timer for targets The timer information for targets can be set up by the procedure below 1 Choose a target which you want to set the timer 2 Select Timer setting from Target menu Timer selection dialog box will appear as the below figure Check in a check box of an event to carry out 3 When you want to add events click Add button In...

Page 17: ...ch setting Monitoring information Items Description Monitoring interval Sets up the interval of the polling in minute unit 1 to 99 minutes can be set Temperature unit Sets up the display temperature unit Centigrade or Fahrenheit Event reception process Sets up the treatment when the event ALERT TRAP SYSERR happens on the target For further information refer to the item About event treatment p 26 p...

Page 18: ...on mail address when the event ALERT TRAP SYSERR happens on the target The mail address entering window appears when clicking Add button E mail information 0 If Send e mail check box of Event reception process on Monitoring information is un checked the alert e mail will not be sent even if you set up the e mail address 0 Up to 10 addresses can be set up for the destination mail address 0 For the ...

Page 19: ...ut status Input signal status Signal No signal Signal interrupted Inside Temperature A status Status of inside temperature A Normal Warning Error Inside Temperature B status Status of inside temperature B Normal Warning Error Inside Temperature C status Status of inside temperature C Normal Error External Temperature status Status of external temperature Normal Warning Error Lamp1 status Status of...

Page 20: ...atus of the network equipment ON OFF Power management Power management status of the network equipment OFF READY SHUTDOWN Monitor out Monitor out status of the network equipment ON OFF Shutter Shutter status of the network equipment OFF High Contrast Normal Shutter management Shutter management status of the network equipment Shutdown Fan control Fan control status of the network equipment Normal ...

Page 21: ... name you want to change the order and move it on a new place and drop it To change column width set a mouse cursor onto the right edge of the col umn to change drag the mouse on it and adjust the column width Sorting the status list The order of the targets on the status list can be changed by clicking the column name which you want to sort It switches ascending or descending order by clicking th...

Page 22: ...rt informa tion of all the targets which are having an alert is listed on this window as the below 2 To export the alert information as text file CSV file click Export button 0 Column width can be changed with dragging the right edge of the column The column order can be changed with drag and drop the column Column can not be deleted ...

Page 23: ...dress IP address of the network equipment Event Type of the Event ALERT TRAP SYSERR See table on the next page Type Type of the Event See table on the next page Warning column Warning column of the Event See table on the next page Warning value Warning value of the Event See table on the next page Unit Displays unit of the warning value Event log information items 0 The listed items are fixed 0 Th...

Page 24: ...Failure LampReplace Replace PowerOFF PowreFailure PowerManagement ShutterManagement Power status Normal Standby Normal OnCoolingDown PowerFailure Power management ShutterManagement ShutterManagement OnCoolingDown TemperatureError Inside Temperature status A to C External Temperature status Abnormal SignalIsInterrupted Input status SignalIsInterrupted LampReplacementTime Lamp time 1 4 lamp time Fil...

Page 25: ...r TemperatureError The projector turned off due to temperature error occurred Normal AfterTempError Normal after temperature error occurred RS232CFailure The RS 232C communication error occurred Power management The power management function turned projector lamp off Shutter management The shutter management function turned projector lamp off LampFailure The lamp failure occurred Normal Standby Pr...

Page 26: ...92 168 1 101 Event ALERT Type ON Warning column Power status Warning value Power failure Notes on using Windows XP Service Pack 2 SP2 Windows Vista Windows Firewall is turned on by default in Windows XP SP2 and Windows Vista Due to this Windows Firewall the send e mail function is not available When using this mail function you need to cancel the block for PJ Network Manager application For the fu...

Page 27: ... On the confirmation dialog box click Yes button to execute deletion 0 The listed items are fixed 0 Column width can be changed by dragging the right edge of the column The column order can be changed with drag and drop the column Column cannot be deleted 0 Up to 1000 of events can be stored If it exceeds 1000 events the oldest event is deleted and the latest event is added Command history Items D...

Page 28: ...nformation system setting and event log information into the man agement file with a free file name It is useful if you manage multiple equipment in the net work Click button on the tool bar and save it with free file name The extension is pnm The management file contains following information Items Description Header Management file section file version System default setting Default value of the...

Page 29: ...tem menu The target batch registration win dow appears 2 Click Reference button and select a defined file to import the target information The imported target information will be listed on the target batch registration window If there is an error in the imported defined file the error information will be indicated on the Result column Retry importing after correcting the defined file 3 Click OK bu...

Page 30: ...s 192 168 0 1 etc Community Name of SNMP community Default value of our network products is public Example of the defined file The table below shows the example of the defined file provided with the target informa tion Save this file as the CSV file Proj_01 192 168 0 1 public Proj_02 192 168 0 2 public Proj_03 192 168 0 3 public Proj_04 192 168 0 6 public Proj_05 192 168 0 7 public PDP_01 192 168 ...

Page 31: ...computer launches web browser and displays the login window of the target equipment You can control and set up the projector remotely by using the web browser For the fur ther information of instruction see the separated network owner s manual Login by dou ble clicking 0 An example of the login page Login to the target equipment ...

Page 32: ...PM KL5AC PJ NETWORK MANAGER OWNER S MANUAL FOR WINDOWS SANYO Electric Co Ltd ...