-7-
Maintenance
Air filter care and cleaning
Air filters prevent dust from accumulating on the optical elements inside the projector. Should the air filters become
clogged with dust particles, it will reduce cooling fans’ effectiveness and may result in internal heat build up and ad-
versely affect the life of the projector. Clean the air filters following the steps below.
Air filters
Pull up and remove.
RECoMMENdAtIoN:
We recommend avoiding dusty/smoky environments
when operating the projector. Usage in these
environments may cause poor image quality.
When using the projector under dusty or smoky conditions, dust may accumulate on a lens, LCD panels, or optical
elements inside the projector. This condition may degrade the quality of a projected image.
When the symptoms above are noticed, contact your authorized dealer or service station for proper cleaning.
CAUtIoN:
Do not operate the projector with the air filters removed.
Dust may accumulate on the LCD panel and the projection
mirror degrading picture quality.
Do not put small parts into the air intake vents. It may result
in malfunction of the projector.
1. Turn off the projector, and disconnect the AC power cord
from the AC outlet.
. Turn over the projector and remove the air filters by pulling
the latches upward.
3. Clean the air filters with a brush or rinse them softly.
4. When cleaning the air filters by rinsing, dry them well. Re-
place the air filters properly. Make sure that the air filters
are fully inserted.
Be sure to reset the Filter counter after cleaning or replacing the filters.
Press the MENU button to display the On-Screen
Menu. Use the Point
7 8
buttons to move the red
frame pointer to the Setting Menu icon.
Use the Point
ed
buttons to move the red frame
pointer to Filter counter and then press the SELECT
button. A dialog box appears showing the total
accumulated time of the filter use, a timer setting
option, and the reset option. Select Reset and the
“Filter counter Reset?” appears. Select [Yes] to
continue.
1
2
Resetting the Filter Counter
Filter counter
Another confirmation dialog box appears, select [Yes]
to reset the Filter counter.
3
Select Reset and
the “Filter counter
Reset?” appears.
Select [Yes],
then another
confirmation
box appears.
Select [Yes] again
to reset the Filter
counter.
Summary of Contents for PLC-WXE46A
Page 63: ... 63 IC Block Diagrams MP2106 DC DC Converter IC5821 IC5861 FA5502 P F Control IC621 ...
Page 65: ... 65 IC Block Diagrams L3E07111 LCD Driver Gamma Correction IC401 NJW1156 Audio Control IC5001 ...
Page 67: ... 67 IC Block Diagrams MR4010 Power OSC IC631 PIC18F67J60 LAN CONTROL IC8801 ...
Page 68: ... 68 XR16L5701IL24 UART IC9885 IC Block Diagrams ...
Page 94: ... KM5AE KM5AF December 2009 DC 200 Printed in Japan SANYO Electric Co Ltd ...
Page 106: ...A10 SCH_KM5AE SCH_KM5AF NO DATA ...