-44-
Electrical Adjustments
Group/
Item
Item Name
Function
Initial
Range Note
0 Temp A Warning Offset
(Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X
minute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
3
0-100
1 Temp B Warning Offset
(Time)
3
0-100
Temp C Warning Offset
(Time)
3
0-100
3 Temp B-A Warning Offset
(Time)
3
0-100
4 Temp C-A Warning Offset
(Time)
3
0-100
Group
254
Fan Control Range Setting (temp./Voltage)
Normal Ceiling HiLand-
Normal
HiLand-
Ceiling
10 Normal Fan Control Min
Temp
Temp Senser Control Start/End Tem.
p at Normal
46
45
39
38
0-100
11 Normal Fan Control Max
Temp
50
49
44
43
0-100
1 Normal Fan1 Min
Fan voltage value at Normal (unit:
0.1V)
7
7
115
115
0-55
13 Normal Fan1 Max
135
135
135
135
0-55
14 Normal Fan Min
80
80
110
110
0-55
15 Normal Fan Max
130
130
130
130
0-55
0 Eco Fan Control Min Temp
Temp Senser Control Start/End Tem.
p at Eco
46
45
39
38
0-100
1 Eco Fan Control Max Temp
50
49
44
43
0-100
Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
5
5
100
100
0-55
3 Eco Fan1 Max
115
115
10
10
0-55
4 Eco Fan Min
65
65
75
75
0-55
5 Eco Fan Max
85
85
91
91
0-55
Group
255
Fan Start/Cooling Setting
0 Fan1 Initial Volt
Fan Start Voltage (0.1V)
70
0-55
1 Fan Initial Volt
70
0-55
4 Fan1 Cooling Speed
Fan Voltage at Power Off (0.1V)
100
0-55
5 Fan Cooling Speed
100
0-55
8 Cooling Time L1
Cooling Time stting at Fan Mode L1 (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
3
1-15
9 Cooling Time L
Cooling Time stting at Fan Mode L (x
30 sec) 1: 30, 3: 90, 15: 450 sec.
4
1-15
10 Temp Error Cooling Time
Cooling Time setting at Temp Erro (x
30 sec)
4
1-15
11 OnStart Cooling Start
Threshold
38
0-100
1 After shutdown cooling
Cooling after shutdown (0: No, 1: Yes)
1
0-1
Group
256
Fan Lamp Voltage down Setting
0 Lamp Voltage
Current Lamp Voltage (0.1V)(Read
only)
-
0-55
1 Lamp Vol Threshold
Threshold to judge Lamp Voltage
Down ( V×10)
0
30-90
Fan1 Speed Gain
Additional Fan Speed of Min at Lamp
Voltage Down (unit: 0.1V)
10
0-55
3 Fan Speed Gain
10
0-55
Group
257
Fan dimmer Setting
0 Dimmer Average Chech
Period
Dimmer Average measurement Time
(0:10sec. 1:30sec. :60 sec. 90:
sec...10:30sec.)
1
0-10
1 Dimmer Average
Dimmer Average Value (Read only)
-
Last Voltage Difference
-
3 Voltage Difference Goal
-
Group
258
FAN network mode IC temp.
0 Standby Cooling Check
Cycle
Standby Cooling Check Cycle
5
-
1 Standy Cooling Start
Threshold
Standy Cooling Start
Threshold
55
-
Standby Cooling Enable
Standby Cooling Enable
1
-
Group
260
Auto Calibration (Common)* Auto Calibration
0 Execute Calibration
0
0-1
Executes Auto-Calibration when
changiing the Value (PC White
100%)
Summary of Contents for PLC-WXE46A
Page 63: ... 63 IC Block Diagrams MP2106 DC DC Converter IC5821 IC5861 FA5502 P F Control IC621 ...
Page 65: ... 65 IC Block Diagrams L3E07111 LCD Driver Gamma Correction IC401 NJW1156 Audio Control IC5001 ...
Page 67: ... 67 IC Block Diagrams MR4010 Power OSC IC631 PIC18F67J60 LAN CONTROL IC8801 ...
Page 68: ... 68 XR16L5701IL24 UART IC9885 IC Block Diagrams ...
Page 94: ... KM5AE KM5AF December 2009 DC 200 Printed in Japan SANYO Electric Co Ltd ...
Page 106: ...A10 SCH_KM5AE SCH_KM5AF NO DATA ...