-19-
8.
LCD panel, Polarized glass, Optical filter removal.
Optical unit disassemblies
A
A
A
A
A
A
A
A
A
B
B
B
LCD panel (Green)
LCD panel (Blue)
LCD panel (Red)
Stopper
Stopper
Stopper
Op
tical filter
Polarized glass(Hout)
Polarized glass(out)
1.
Remove 9 screws-A and remove the LCD panel . (3 screws per one LCD panel.)
2. Remove 3 screws-B and remove stoppers.
3. Remove polarized glasses,optical filteres upward.
Note: Each polarizer unit uses different characteristic polarization glasses. Mark the polarizer units as they are removed from the optical
unit so that they may be reassembled in the same location from which they were removed.
Caution :
(1). Never touch the LCD panel directly with hand. Otherwise the optical parts may get dirty.
(2). Since the LCD panel is equipped with CMOS-LSI, pay attention to static electricity.
And never touch the electrode of flexible cables.
Note :
Don't remove all three LCD panels at the same time. The standard in convergence
adjustment runs out and it becomes not possible to do an adjustment.
When exchanging three LCD panels at the same time, it recommends to exchange every
in the Prism/LCD panel assembly.
Summary of Contents for PLC-UF15
Page 69: ... 69 CXA3562R LCD DRIVER FF ...
Page 108: ...SANYO Electric Co Ltd Jan 2003 Printed in Japan ...
Page 148: ...Diagrams Drawings MT8 UF1500 ...