9
Service Mode
Service Menu Function (1)
Service Menu Display Method
There are 2 display methods.
Method 1
While pressing the "Volume -" button on the unit, press the RECALL button on the remote control 3 times.
(If the interval when pressing the RECALL button exceeds 1 second, then it is disabled.)
Method 2
1) Press the OFF TIMER button and then set the off timer.
2) Press the volume button and then set the volume to "0."
3) While the volume bar is being displayed, press and hold the screen display button for 3 seconds.
The service information is displayed.
Internal Temperature
The internal temperature of the product is displayed.
Power Error Information
䊶
The number of times that a power error has occurred is displayed.
䊶
If a power error is detected, the settings switch to stand-by status.
䊶
The power button on the monitor unit can be used for power on/off.
Panel Used Time
The elapsed time the LCD panel is used is displayed.
Temperature Error
䊶
The number of times that a temperature error has occurred is displayed.
䊶
If a temperature error is detected, the settings switch to stand-by status.
Digital Power Management
Off: The power management function does not work on the DVI input screen
On: The power management function works on the DVI input screen
Caution:
Panel test
Start can be performed with the auto display mode on the LCD panel.
Press and select with the buttons
䂥
/
䂯
, and if "On" is selected by pressing the buttons :
䊶
The auto display mode starts.
䊶
When the power is turned off, the panel test returns to "Off."
Press and select with the buttons
䂥
/
䂯
, and setting can be performed by
pressing the buttons .
When setting to on, the energy star and DPMS standard cannot be achieved
because the power consumption during stand-by status increases.
䊶
When the auto display mode is terminated, the power is turned off with power button on the remote control or the monitor unit.
䊶
If the power is turned on with the remote control and the power
error is detected 3 consecutive times, as a consequence, power
on cannot be performed with remote control.
䊶
When the power on cannot be performed with the remote control,
if the AC cord is disconnected, it resets this status.
䊶
Recovery from stand-by status can be performed with the power button
on the remote control.
The power management function can be set by using the operations
on the DVI input screen.
䂥䋯䂯䇮
OFF TIMER
RECALL
Volume
Service Menu