PDG-DHT8000L Expand Serial Command Functional Specifications
83/101
9.10.10 CR_RSENS Command
Command “CR_RSENS” [CR]
Details
Get selected location of infrared remote receiver of remote control
Acceptable
“000_%1” [CR]
%1
“ALL” ------------------ Front and back and top parts are valid
“FRONTTOP” ------- Both front and top parts are valid
“BACKTOP” --------- Both back and top parts are valid
“FRONTBACK” ----- Both front and back parts are valid
“FRONT” ------------- Only front part is valid
“TOP” ----------------- Only top part is valid
“BACK” --------------- Only back part is valid
Response
Unacceptable “?” [CR]
9.10.11 CR_P-MANE Command
Command “CR_P-MANE” [CR]
Details
Get setting status of Power management
Acceptable
“000_%1” [CR]
%1
“OFF” ------------------------ Power Management is disabled
“READY” -------------------- Power Management is set to Ready
“SHUTDOWN” -----Power Management is set to Shut Down mode
Response
Unacceptable “?” [CR]
9.10.12 CR_P-MANETIME Command
Command “CR_P-MAETIME” [CR]
Details
Get setting time for starting Power Management function
Acceptable
“000_%1” [CR]
%1
“001 – 030” ----------------------- 1 to 30 minutes
Response
Unacceptable “?” [CR]
9.10.13 CR_ONSTA Command
Command “CR_ON-STA” [CR]
Details
Get Power ON Start setting status
Acceptable
“000_%1” [CR]
%1
“ON” -------------------------- Power ON Start is set to ON.
“OFF” ------------------------ Power ON Start is set to OFF.
Response
Unacceptable “?” [CR]
9.10.14 CR_SECURITY Command
Command “CR_ SECURITY” [CR]
Details
Get ON/OFF setting status of Security on menu.
Acceptable
“000_%1” [CR]
%1
“ON” ------------ PJ is locked
“OFF” ----------- PJ is not locked.
Response