- 63 -
25
ROUTINE MAINTENANCE
Replacement of glow starter
A glow starter is located inside the front cover.
1.
Disconnect the power supply plug.
2.
Remove the water-proof rubber.
3.
Remove the glow starter and replace with a new one.
4.
Replace the water-proof rubber.
Cleaning of condenser filter
1.
Lift the front cover as shown in the figure.
2.
Take out the shaft and insert the end of the shaft in
the black hole of the front cover.
3.
After holding black handle of condenser filter, and
having raised it aloft, remove the condenser filter.
4.
Absorb a dirt of condenser filter with leaning machine,
or wash it away with water.
5.
Cut water of condenser filter well when used water.
6.
After cleaning the condenser filter, return it to the
original position.
Socket
Water-proof rubber
Condenser
filt
Front