4 User menu setup before leaving factory
Enter into page
“LOCK
” of user menu, select submenu item “
Restore Factory Default
” to preset
items before leaving factory as below:
a) Clear out all programs information;
b) Clear out information of parental control (
VCHIP
);
c) Default setup of user analog data;
d) Set Menu Language as
English
;
e) Set Power on MODE as
Off
.
Instruction of factory software burning as
Table 6
Table 6
Instruction of factory software burning
No.
Part No.
Part type
Instruction of
software
function
Burned
before
SMT
Burning method
N111 5272564002 EN25Q64-104HIP FLASH Yes
burned with program
ALL1
1
, write-protect setup,
refer to
Note 1
in detail
N108 5272404002
AT24C04
HDMI KEY
Yes
burned with program
ALL1
1
NA04 5272402002
AT24C02
HDMI EDID
Yes
burned with program
ALL1
1
NA05 5272402002
AT24C02
HDMI EDID
Yes
burned with program
ALL1
1
NA06 5272402002 AT24C02
HDMI EDID
(supporting
the 3rd HDMI)
Yes
burned with program
ALL1
1
N106 5272402002
AT24C02
VGA EDID
Yes
burned with program
ALL1
1
Note 1:
Write-protect setup method
Enter into burning interface of
program
ALL-100
, select item “
Config
”, press item “
config
Setting”
, set item “
Protect
” as “
All Protect
”; be sure to select item “
Config
” before burning
software, and write-protect must be re-set after burning program
ALL-100
startup every time.
Note 2:
Burning and upgrading software method with burning tool
ISP
Method of software upgrading