- 5 -
Measure the resistance: Across two terminals with
an ohm-meter on highest scale.
COMPONENT
HIGH-VOLTAGE
CAPACITOR
Including
bleeder
resistor
HIGH-VOLTAGE
DIODE
Measure the resistance: Across two terminals with
an ohm-meter on highest scale.
CHECKOUT PROCEDURE
RESULT
Normal reading:
Momentarily indicates several ohms, and
gradually to 10 meg-ohms.
Abnormal reading:
Indicates continuity or 10 meg-ohms
from the beginning.
Normal reading:
Indicate about the middle position in one
direct (forward) and infinite ohms in the
reverse direction, using meter with a 9-
volt battery.
NOTE
- Some digital meter may show over even
in a forward direction because low mea-
suring voltage of meter does not allow
the meter to pass through the high volt-
age diode.
Abnormal reading:
Indicates continuity or infinite ohms in
both directions.
FUSE DIODE
Measure the resistance: Across two terminals with
an ohm-meter on highest scale.
Normal reading:
Indicate infinite ohms in both directions.
Abnormal reading:
Indicates continuity in both directions or
continuity in one direction and infinite ohms
in reversed direction.