![Sanyo DSR-M814 Service Manual Download Page 9](http://html.mh-extra.com/html/sanyo/dsr-m814/dsr-m814_service-manual_360874009.webp)
−
9
−
Z3001
VR105
S3001
CN309
TP131
VR134
VR133
VR132
VR131
3-5. CH4 INPUT SIGNAL LEVEL ADJUSTMENT
1. Input a color bar signal containing 100% white to the CH4
input terminal.
2. Select "CH4" and switch to full screen mode.
3. Connect a 75
Ω
termination to the MONITOR OUT
connector and connect an oscilloscope.
4. Use VR134 to adjust until the 100% white level from the
sync chip for the Y signal is 1.00
±
0.04 Vp-p.
Measuring Point Measuring Equipment
Condition
Adj. Value
OSCILLOSCOPE
POWER ON
E-E Mode
1.00 V
±
0.04 V p-p
VR134 (CP-1 board)
Adj. Location
MONITOR OUT
1.00
±
0.04
Vp-p
3-6. CP-1 BOARD LOCATIONS OF ADJUSTMENT POINTS
CP-1 BOARD
FRONT SIDE
Summary of Contents for DSR-M814