Specifications
Please note that specifications and unit exterior design
are subject to change without notification.
b
Character table for Camera title
b
Dimensions (unit: mm)
b
Options
HDD: 80GB/160GB/300GB/500GB
CD-R/RW: Expanded disc unit
Signal method
PAL signal standard
Compression method
Video: M-JPEG, Audio: WAVE
Number of pixels
720 x 288
Recording type
Field record
Recording quality
5 stage [BASIC/NORMAL/ENHANCED/
FINE/SUPER FINE]
Recording rate
27 levels (50 to 0.033FPS)
Recording area
Normal recording area/alarm recording
area/archive area
Zoom
2x digital zoom is possible using the
ZOOM button
Search mode
Date and time search, alarm search,
alarm thumbnail search, archive area
search, motion detection search
Date/time display
Day, month, year, hour, minute, second
Date/time display
position
Can be moved to upper and lower (2)
positions (Display can be switched on/off)
Camera title display
10 characters max (alphabetical, numeric,
symbols) can be inputted to each channel
(display can be switched on/off)
Memory backup
Approximately 30 days (after power is
supplied for more than 48 hours)
Video input
1.0 V (p-p) 75
Ω
BNC x6
Video output
Through output BNC of each video input
x6
Main monitor output
1.0 V (p-p) 75
Ω
BNC x1
Monitor 2 output
1.0 V (p-p) 75
Ω
BNC x1
Audio input
–8 dBs 27 k
Ω
unbalanced RCA x1
Audio output
–8 dBs 600 k
Ω
unbalanced RCA x1
Microphone input
–60 dBs 10 k
Ω
unbalanced 3.5 mm
Monaural mini jack x1
Front AV
output
Video output
1.0 Vp-p 75
Ω
unbalanced RCA x 1
Audio output
–8 dBs 600
Ω
unbalanced RCA x 1
A B C D E F G H I
J K L M N O P Q R S T U
V W X Y Z 0 1 2 3 4 5 6 7 8 9
-
:
.
/
*
CompactFlash slot
CompactFlash Type 2 (front panel) x1
Terminal
LAN
10BASE-T/100BASE-TX, RJ-45 x1,
compatible protocol: UDP, TCP/IP, HTTP
server
RS-485
RJ-11 x2 (with termination switch)
USB (1.1 A terminal)
Front 1/Rear 1
Alarm input
Zero voltage make connection (pulse
width 100m/second and over) x6
Sensor alarm output
Open collector/1k
Ω
, Low level active
(max. 25 mA) x6
Remote control input
2 wire voltage control method x2
Clock adjustment
input
Zero voltage contact (pulse width 100m/
second and over) x1
Clock adjustment
output
Open collector/1k
Ω
, Low level active
Alarm total output
Open collector/Low level active (max.
500 mA) x1
Alarm reset input
Zero voltage contact (pulse width 100m/
second and over) x1
Abnormality warning
output
Normal DC 5V, Low level active x1
Normal recording
area remaining
warning output
Normal DC 5V, Low level active x1
Alarm recording area
remaining warning
output
Normal DC 5V, Low level active x1
Series recording
connecting input
Normal DC 5V, Low level active x1
Series recording
connecting output
Open collector/1k
Ω
, Low level active x1
External timer input
Zero voltage contact (pulse width 100m/
second and over) x1
Non rec output
Normal DC 5V, Low level active x1
Power supply voltage
AC 120 – 240 V, 50/60 Hz
Current consumption
800 mA
Allowable operation
temperature
5 to 40°C
Allowable operation
humidity
10 to 80 %
Dimensions
420 (W) x 86 (H) x 365 (D) mm
Weight
Approx. 6 kg
420
365
86