4
WM – 700699
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
Rating conditions are: Outside air temperature 95°F DB/75°F WB
Indoor unit entering air temperature 80°F DB/67°F WB
Model No.
KMS1812
Type
Wall-mounted
Cooling
Capacity
BTU/h
18,000 / 17,600
kW
5.27 / 5.16
Air circulation (High)
cu. ft./min.
440 / 420
Moisture removal (High)
pints/h
5.3 / 5.2
Phase, Frequency
Hz
Single, 60
Voltage rating
V
230 / 208
Available voltage range
V
187 to 253
Controls
Microprocessor
Control unit
Wireless remote control unit
Temperature control
IC thermostat
Timer
ON/OFF 24-hours & Program
Fan speeds
3
Air deflector
Horizontal / Vertical
Manual / Manual
Air filter
Washable, easy access
Operation sound
Hi / Me / Lo
dB-A
47 / 44 / 40
Refrigerant tubing connections
Flare type
Refrigerant tube o.d.
Narrow tube
in. (mm)
1/4 (6.35)
Wide tube
in. (mm)
1/2 (12.7)
Refrigerant tube kit
Optional
Accessories
Hanging wall bracket
Height
in. (mm)
14-3/16 (360)
Width
in. (mm)
38-31/32 (990)
Depth
in. (mm)
7-25/32 (198)
Net weight
lbs. (kg)
30 (13.5)
Shipping volume
cu. ft. (cu. m)
4.8 (0.136)
Shipping weight
lbs. (kg)
37 (17)
Performance
Electrical
Rating
Features
Dimensions &
Weight
Applicable Indoor Unit
92-131 S/M (Basic) 2/21/01 4:49 PM Page 4