background image

3

CAUTION:

 Please read and retain for your safety.

 This unit has been designed and manufactured to assure your personal safety, but 

improper use can result in potential electric shock or fire hazards. In order not to defeat the safeguards incorporated in this monitor observe the 

following basic rules for its installation, use and servicing .

Installation and Use

Do not

 allow anything to rest on the power 

cord . 

Do not

 locate this LCD monitor where the 

cord will be damaged by people walking on it .

Do not 

overload wall outlets and extension 

cords as this can result in fire or electric shock.

A suitable socket outlet must be provided near 
to the monitor and shall be easily accessible .

Do not

 place this LCD monitor near any heat 

sources such as radiators, heaters, stoves and other heat-generating 

products (including amplifiers). 

Do not

 place your LCD monitor on an unstable stand, shelf or table . 

Serious injury to an individual, and damage to the LCD monitor may 
result if it should fall . Your sales person can recommend an approved 
wall mounting kit . A special wall mounting kit is available for this 
model .

This

 LCD monitor should be operated only from the type of power 

source indicated on the monitor or as indicated in the Operating In-
structions . If you are not sure of the type of power supply, consult your 
sales person or your local power company .

For added protection

 it is strongly recommended that this LCD 

monitor has its mains supplied via an approved earth fault protection 
device .

WARNING:

 To prevent injury the LCD monitor must be securely 

attached to the wall in accordance with the manufacturers installation 
instructions .

IMPORTANT:

This product must be earthed.

This unit is not disconnected from the mains unless the mains lead 
is unplugged . The installer must make sure that the waterproof inline 
coupler is easily accessible .

This monitor is tested to 

IP66

 standard rating .

This monitor is 

not

 protected against temporary or continuous 

immersion in liquid .

Do not

 use immediately after moving the LCD monitor from a low 

temperature to a high temperature environment, as this causes con-

densation, which may result in fire, electric shock, or other hazards. 

Before cleaning, unplug the monitor from the wall socket . 

Do not

 mount near an open flame source. Open flames must never 

be used near this LCD monitor .

This LCD monitor

 should not be built in or enclosed in any way, heat 

build up will reduce the life of the monitor .

This LCD monitor should have a minimum distance of 5cm away from 
the wall and the monitor should have 10cm distance around the top 
and sides .

Always

 mount using recommended and substantial fixtures and fit

-

tings .

10cm

10cm

10cm

5cm

The rear finned section around the cabinet functions as a heat sink, 

removing heat away from the monitor . The external surface of the 

cabinet (finned area) must not be covered or the airflow restricted in 

anyway by enclosing the LCD monitor .

The operating temperature range of this monitor is guaranteed 0°C 
~ 40°C/32°F ~ 104°F . It is not recommended to install the screen 
in direct sunlight without adequate shading, as this will cause the 

temperature of the panel to rise above the maximum specified. 

Doing so may cause a black shadow to appear on the screen which 
will disappear when the screen temperature returns to within the 

specification. This “of course” does not produce any harmful effect on 

the lifetime of the monitor .

Do not

 apply liquid cleaners or aerosol cleaners directly onto the LCD 

monitor . Use a damp cloth for cleaning .

ADDITIONAL FOR NORTH AMERICA AND CANADA:

This

 monitor must 

NOT

 be permanently mounted to the building 

structure . It must be mounted in such a way that it can be removed 
using basic tools .

The

 power supply cord must 

NOT

 be attached to the building surface . 

The power supply cord must 

NOT

 be routed through walls, ceiling, 

floors, or other similar openings in the building structure. 

The

 power supply cord 

MUST

 be positioned so as to prevent physical 

damage .

Important: (UK only)

THIS PRODUCT MUST BE EARTHED.

This equipment is fitted with an approved mains lead and an 

approved non rewireable UK mains plug . To change a fuse in this 
type of plug proceed as follows:

1.

 Remove the fuse cover and fuse .

2.

  Fit a new fuse which should be a BS1362 13 Amp A .S .T .A . or 

BSI approved type .

3.

 Ensure that the fuse cover is correctly refitted.

If the fuse cover is lost or damaged the plug must 

NOT

 be used 

but replaced with a serviceable plug .

If the fitted plug is not suitable for your socket outlets, it should be 
cut off and an appropriate plug fitted in its place. If the mains plug 

contains a fuse, this should have a rating of 13 Amp, ensure the 

fuse cover is correctly fitted. If a plug without a fuse is used, the 

fuse at the distribution board should not be greater than 13 Amp .

Note:

 The severed plug must be destroyed to avoid a possible 

shock hazard should it be inserted into a 13 Amp socket else-
where .

The wires in this mains lead are coloured in accordance with the 
following code:

 

Blue 

Neutral

 

Brown 

Live

 

Green and Yellow 

Earth

1.

  The Blue wire must be connected to the terminal which is 

marked with the letter “N” or coloured BLACK .

2.

  The Brown wire must be connected to the terminal with the 

letter “L” or coloured RED .

3.

  The Green and Yellow wire must be connected to the terminal 

which is marked with the letter “E” or coloured GREEN or 
GREEN and YELLOW .

Before replacing the plug cover, make certain that the cord grip is 
clamped over the sheath of the lead - not simply over the wires .

Do not

 attempt to bypass the safety purpose of the grounding 

type plug .

THIS UNIT IS NOT DISCONNECTED FROM THE MAINS UN-
LESS THE MAINS LEAD IS UNPLUGGED.
THE INSTALLER MUST MAKE SURE THE MAINS LEAD IS 
EASILY ACCESSIBLE.

SAFETY PRECAUTIONS

GB

GB

Summary of Contents for CE52LH2WP

Page 1: ...INSTRUCTION MANUAL LCD Monitor Please read this Instruction book before using your LCD monitor We wish you many hours of pleasure from your new LCD monitor CE52LH2WP CE52SR3 ...

Page 2: ...glass This offers the protection for the panel surface in the public display circumstance ALUMINUM CABINET NON HOLES DESIGN This monitor set uses Anodized aluminum and it has quite unique Non Holes ventilation design which protect against mischief in the public display applications and less maintenance from dust and oil circumstance and having perfect protection of IP66 weather resistant approval ...

Page 3: ...om the monitor The external surface of the cabinet finned area must not be covered or the airflow restricted in anyway by enclosing the LCD monitor The operating temperature range of this monitor is guaranteed 0 C 40 C 32 F 104 F It is not recommended to install the screen in direct sunlight without adequate shading as this will cause the temperature of the panel to rise above the maximum specifie...

Page 4: ... These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is lik...

Page 5: ...ership rights in the Software to you The Software provided hereunder may contain or be derived from portions of materials provided to SANYO under license by a third party supplier 5 Except as expressly permitted by statute you may not use the Software in conjunction with any other computer hardware other than the product copy all or part of the Software incorporate all or any of the Software into ...

Page 6: ...selecting AV2 Setting in Set up menu see page 10 You can connect your DVD player to the Y Pb Pr terminals instead of using a scart lead This can support high definition in analogue component form RGB H V can be used as a PC input via the BNC terminals Both options support a large range of resolutions page 17 AV2 OUT can be used to output the incoming AV2 signal to the other monitor 4 AV3 Composite...

Page 7: ... viewing mode Dynamic Suitable for brightly lit rooms Soft Low contrast setting Eco Suitable for dimly lit rooms and gives a cin ema like effect Freeze To switch picture still on or off Green Press this button for more than 5 seconds installa tion mode will appear Remote control Remote control battery installation Install two AA 1 5 volt batteries so that the and marks on the batteries match the a...

Page 8: ...ogram AV1 RGB AV2 AV3 PC DVI Network Menu Setup PIP POP Setup Initial Settings Text Language Tile Mode AV2 Setting Western Eastern Russian Arabic Farsi Tile Mode Active H V_Sets H V Location Bezel H V Adjustment RGBHV YPbPr Auto Adjust H Position V Position Clock Phase Language H V Position Duration Transparence PIP POP Mode Main Sub Source PIP Position Time Action Active Power On Power Off On Off...

Page 9: ...button to enter Press the BACK but ton to return to the previous menu Press the MENU button to exit menu operation n Current Weekday Use to set current weekday using the 1 or 2 button n Current Time Use to set the current time using the Numeric buttons Other items in Time Menu should not be selected until Current Time has been set n Schedule Use to set up to 20 separate time schedules for Power On...

Page 10: ...e the vertical picture into more than one part and the most is also 5 parts 5 monitors Using the 1 or 2 but ton to set H Location is used to select one part of the horizonal picture to dis play on the current LCD Monitor using the 1 or 2 button V Location is used to select one part of the vertical picture to display on the current LCD Monitor using the 1 or 2 button Bezel H Adjustment is used to a...

Page 11: ...ppear if buttons are pressed when child lock is On Standby operates normally when childlock is set On n Address Set the address for the LCD monitor 0 999 Setting the monitor address in RS232 mode Each monitor can have a specific Address which helps command that monitor individually and will not effect to other monitors con nected to a controlling PC Address format command The addressing format com...

Page 12: ...ed even more to allow subtitles to be seen As Zoom 16 9 but bottom is compressed even more to allow subtitles to be seen As Zoom 16 9 but bottom is compressed even more to allow subtitles to be seen As Zoom 16 9 but bottom is compressed even more to allow subtitles to be seen 4 3 14 9 16 9 Letterbox Video The correct picture width is maintained but the top and bot tom are cropped Zooms in slightly...

Page 13: ...POP mode press the Main Sub Picture Swap but ton will switch the location for main and sub picture Only the sound on the main picture is heard from the monitor speaker The sound on the sub picture cannot be heard The details for PIP POP operation eg location for sub picture or input source for any picture etc please refer to page 10 n PIP1 mode n OFF mode n PIP2 mode n POP mode The left picture is...

Page 14: ... ture appears on the screen Press this button once again or press TXT TV button CANCEL mode will be cancelled In CANCEL mode CAN is always displayed on the upper left of the screen Text Hold Press Text Hold button to stop page request and updating HOLD ON The Hold symbol will appear instead of the page number Update of TELETEXT is forbidden It holds on the current TEXT screen display now HOLD OFF ...

Page 15: ... in standby mode n POOR PICTURE Adjust BRIGHTNESS CONTRAST levels too low n NO COLOUR PICTURE OK Adjust COLOUR control Check lead connections Does the signal input have colour n REMOTE CONTROL DOES NOT WORK Check batteries are inserted correctly Check condition of batteries Check to see if remote control inhibit is set ON n PICTURE OK NO SOUND Check external speakers are connected correctly Check ...

Page 16: ... 4 105 RC RECEIVER 217 193 8 176 7 Control buttons Unit mm 648 712 5 800 800 516 210 3 140 280 420 1304 M6 WALL BRACKET FIXING 140 280 420 560 286 8 373 3 310 9 wer LED 90 19 10 4 105 EIVER Handles x 4 Cables exit terminal cover 1120 6 997 376 5 358 4 117 6 16 9 36 4 229 6 233 9 Control buttons GB GB ...

Page 17: ... x 400 31 47 70 09 DOS VGA 640 x 480 31 43 59 88 VGA VESA 60Hz 640 x 480 37 50 75 00 VGA VESA 75Hz 640 x 480 37 86 72 81 VGA VESA 72Hz 640 x 480 43 27 85 00 VGA VESA 85Hz 640 x 480 35 00 66 67 Mac 13 640 x 480 34 97 66 60 Mac LC 13 800 x 600 35 16 56 25 SVGA VESA 56Hz 800 x 600 37 88 60 32 SVGA VESA 60Hz 800 x 600 46 875 75 00 SVGA VESA 75Hz 800 x 600 34 50 55 38 SVGA 800 x 600 38 00 60 51 SVGA 80...

Page 18: ...tatus of Contrast CR COLOR Status of Color CR TINT Status of Tint CR SHARP Sharpness CR WBAL Status of White Balance Mode informa tion CR WBAL R Status of White Balance Red CR WBAL G Status of White Balance Green CR WBAL B Status of White Balance Blue CR NZRED Status of Noise reduction setting CR FILM Status of Film mode setting CR IMAGE Status of Image selection The same as PICTURE mode CR DCDI S...

Page 19: ...on Wait and transmit command again 101 The errors not including above n Sound control Read Command Table Status read command Item CR VOLUME Status of volume value CR MUTE Status of MUTE n Other Read Command Table Status read command Item CR STATUS Status of the operation of the monitor CR SIGNAL Status of with or without signal CR FREEZE Status of Freeze setting CR FANLOCK Statuses of fan lock err...

Page 20: ...N7WKS N7WLS SANYO Electric Co Ltd ...