-7-
C5KEV
To select the mode and service item and change data value
+ Highlight the desired adjustment mode by using the P
▲
or P
▼
button and then press the F/OK button.
+ To select the adjustment item, use the P
▲
or P
▼
button.
+ To change the service data, use the Volume -(LEFT) or (RIGHT) button.
+ The data which is set in the service mode is stored into the memory IC automatically.
Exit from the Service Mode
+ Press the RECALL
button or turn off the TV set by using the Mains switch.
INITIALISATION OF MEMORY IC
To initialise the memory IC (IC803), press and hold the NORMAL
button on the remote control, then press
the P
▼
button on the front panel of the TV set and then turn the Mains switch Off and On. The initialisation is now
completed.
When initialised the memory IC and all of the setting data (option data and service adjustment data) stored in the IC
are reset to the default value. It is necessary to set the option settings and readjust the service adjustments listed on
page 6 and to re-tune all the channels.
REGULAR
1, AGC
38
Adjustment No.
and Item name
Adjustment Data
IMAGE
1. P V-P
1F
Adjustment No.
and Item name
Adjustment Data
REGULAR mode
IMAGE mode
?